ELIS PLZEŇ a. s.
Project design, installation and service manual
Page 25 of 72
Electromagnetic flowmeter FLONET FH30xx
ELIS PLZE
Ň a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, phone.: +420 377 517 711, fax: +420 377 517 722
Es 90678K
Flanges according to ASME B16.5
Wafer sensor design
PN
DN
Number of
bolts
Thread
Specified torque
(Nm)
25
4
M12
37
32
4
M16
61
40
4
M16
78
50
4
M16
100
65
8
M16
62
80
8
M16
76
PN16
100
8
M16
84
125
8
M16
112
150
8
M20
161
200
12
M20
147
The flange tightening torque for rubber or E-CTFE-lined sensors depends on the seal material and the
sensor design version. Consult this issue with the seal supplier.
Class
NPS
Number
of bolts
Thread
Specified
torque
(Nm)
150
½“
4
½“, M1
12
¾“
4
½“, M1
18
1“
4
½“, M1
23
1
¼“
4
½“, M1
35
1
½“
4
½“, M1
48
“
4
5
/
8
“, M1
94
½“
4
5
/
8
“, M1
110
3“
4
5
/
8
“, M1
161
4“
8
5
/
8
“, M1
114
5
8
¾“, M 0
160
“
8
¾“, M 0
200
“
8
¾“, M 0
272
10“
12
7
/
8
“, M
255
1 “
12
7
/
8
“, M
340
14“
12
1“, M 4
430
1 “
16
1“, M 4
410
1 “
16
1
1
/
8
“, M30
610
0“
20
1
1
/
8
“, M30
540
4“
20
1 ¼“, M33
765