10.5.1.2 Flanges according to ASME B16.5
Rated
pressure
NPS
D
d
A
L
l
Weight*
(kg)
Class 150
1/2"
88.9
62
172
200
66
3
3/4"
98.6
62
177
200
66
3
1"
108
72
187
200
96
3
1 1/4"
117.3
82
197
200
96
4
1 1/2"
127
92
207
200
96
4
2"
152.4
107
227
200
96
6
2 1/2"
177.8
127
249
200
96
9
3"
190.5
142
263
200
96
14
4"
228.6
162
292
250
96
16
5"
254
192
320
250
126
19
6"
279.4
218
346
300
126
25
8"
342.9
274
405
350
211
41
10"
406.4
370
485
450
211
54
12"
482.6
420
548
500
320
77
14“
533.4
480
604
550
320
92
1 “
596.9
530
660
600
320
116
1 “
635
581
705
600
320
150
0“
698.5
640
766
600
320
167
4“
812.8
760
883
600
320
315
Comment: *