42
English
11.2.2 Removing the chain guard
• Turn the machine off and take the key out
of the ignition.
• Remove the two bolts (1) (M10 slw 17).
• Remove the guard.
11.2.3 Disconnecting the battery
• Disconnect the negative terminal (1) (black
M6 slw 10).
• Disconnect the positive terminal (2) (red
M6 slw 10).
Caution:
First connect the positive terminal (2) (red M6, SW 10).
And then the negative terminal (1) (black M6, SW 10). Never disconnect the
battery for longer than 1 day.
11.2.4 Opening the Axelero
TM
chamber
Caution:
Make sure the Axelero
TM
has come to a standstill before opening the Axelero
TM
chamber. Turn the motor off and take the key out of the ignition.