16.3 Troubleshooting - resolving problems
The troubleshooting page on the dashboard indicates both electrical and mechanical faults that
could pose a risk for both operator and machine.
If there is a fault, the Alarm LED will light up, the
LCD screen back-light will blink and an error mes-
sage will appear on the display.
Pressing the ‘Alarm’ button will show the trouble-
shooting page; if there are multiple problems, the
arrow keys can be used to scroll through the list.
The following faults could occur:
16.3.1 F00: Oil Press. Low
If this error message is shown on the display, the oil pressure in the motor is low. Check the oil
level of the motor and replenish if necessary. (read “11.3.1 Checking the oil level in the engine
cra refilling” on page 47)
After carrying out the necessary repair to resolve the fault, the Reset button in the trouble-
shooting menu can be pushed in order to remove the error message.
16.3.2 F01: Safety Cover
If this error message is shown on the display, the maintenance hatch is not correctly closed.
This maintenance hatch is equipped with a safety contact (1) which
ensures that the machine will not start if it is not correctly closed.
Open the Axelero
TM
chamber and shut it correctly. (read “11.2.4
Opening the AxeleroTM chamber” on page 42)
Push the Reset button in the troubleshooting menu to remove this
error message.
If this error message does not disappear, there is a fault in the
safety contact. Order a new part from your distributor with order
number BE 120 030 020
16.3.3 F02: Oil Pr. sensor
If this error message is shown on the display, there is a problem with the oil pressure sensor.
When starting the machine, a check is performed on whether this sensor is working.
If you see this error message, you must contact your distributor.