miniELCOR
75
If are all data in the line set in right way, then is consumption place set and
communication way between PC and device is ready. The user may test
communication with help of actual values reading (menu choice
Readout -> Actual
values
).
14.3.2 Communication channel setting
For successful communication between device and PC must be correctly set
the communication cannel. For communication cannel setting must be chosen
correct communication interface, communication speed, etc.
Setting progress
From menu choose:
Options –> Communication channels
In case of adding a new device in to the set service SW is possible to choose
already defined communication channel or define a new communication
channel with the button „+“ see Fig. 32.
Setting of new communication channel starts with choosing of connection
between device and PC (programme switch
Communication medium
). For
communication via infrared-head choose
RS-232
and relevant communication
port
COM
. After this selection will be the new communication channel added
in the table
Configuration of communication channels
.
Configuration of communication channel:
name of communication channel – here assign your own mark (in case of
more communication channels is it better for its identification)
Speed of communication channel:
communication via infrared-head HIE-03,04 – communication speed up to
38 400 Bd (older model HIE-01 - communication speed 9600 Bd)
communication via serial port – Communication speed up to 38 400 Bd.
communication via modem – communication speed is set according to
communication speed of modem.
Other parameters are without changes.
Basically if user wants to edit the table, change is made with click on item.
Содержание miniELCOR
Страница 13: ...miniELCOR 6 Fig 1 Volume and energy calculations Scheme...
Страница 19: ...miniELCOR 12 Fig 5 Security marks device without SCR encoder Fig 6 Security marks of miniELCOR SCR...
Страница 50: ...miniELCOR 43...
Страница 55: ...miniELCOR 48 Fig 22 Basic navigation from the initial screen FW 2 xx...
Страница 65: ...miniELCOR 58 Fig 26 Mounting of miniElcor to the mounting plate Fig 27 Mounting on the pipeline...
Страница 69: ...miniELCOR 62 Fig 30 Shielding connection in bushing 12 35...
Страница 84: ...miniELCOR 77 Fig 33 Base device parameters Fig 34 Data archive...
Страница 100: ...miniELCOR 93 Fig 50 Wizard for mathematical expression Fig 51 Equation for primary volume pulses and output connection...
Страница 111: ...miniELCOR 104 Fig 64 Switch of communication protocol in the device...
Страница 114: ...miniELCOR 107 Fig 66 Fig 67...
Страница 119: ...miniELCOR 112 Fig 70 Fig 71...
Страница 120: ...miniELCOR 113 Fig 72 Fig 73...
Страница 121: ...miniELCOR 114 Fig 74 Fig 75...
Страница 122: ...miniELCOR 115 Fig 76...
Страница 125: ...miniELCOR 118...