miniELCOR
24
Manual setup of primary volume counter V
m
is not allowed at encoder input..
Installation and replacement of gasmeter
Actual counter of gasmeter is transferred into EVC after connection of encoder
and EVC possibly causing big difference at primary volume Vm. To prevent against
affection of base volume Vb (Vbs) it is necessary to keep following instruction:
1. In service SW 22 display device parameters, select subject „Encoder SCR“
and push button „Encoder exchange“. During encoder exchange will be
stopped processing of primary volume from gasmeter. (Further follow
instructions shown on PC display).
2. Connect physically encoder to EVC.
3. After connection of encoder finish installation/exchange with OK button.
During installation/exchange ( meant from point 1) no differences are added to
appropriate counters which are marked on display with exclamation mark. If point 3 is
not finished by one hour exchange procedure will be closed automatically at service
SW.
5.1.4 Binary inputs
These inputs monitor the input signals with the option of an evaluation of the
condition “connected” (i.e. log. 0) or “disconnected” (log. 1). The device allows the
evaluation of the binary inputs from the no-potential outputs (reed contact or open
collector – these signals are on DI1 and DI2 inputs connected to terminals LF+, LF-)
or from sensors of the type NAMUR (DI1 and DI2 inputs, terminals HF+, HF-) The
NAMUR sensors require an external supply voltage of the converter higher than 7 V
(e.g. from JBZ-02).
By setting the parameter, the user can choose the display of the instantaneous
values on the display, storing the changes of these inputs in the archive; display the
headline for condition log. 0 and log. 1, and active signal level.
Содержание miniELCOR
Страница 13: ...miniELCOR 6 Fig 1 Volume and energy calculations Scheme...
Страница 19: ...miniELCOR 12 Fig 5 Security marks device without SCR encoder Fig 6 Security marks of miniELCOR SCR...
Страница 50: ...miniELCOR 43...
Страница 55: ...miniELCOR 48 Fig 22 Basic navigation from the initial screen FW 2 xx...
Страница 65: ...miniELCOR 58 Fig 26 Mounting of miniElcor to the mounting plate Fig 27 Mounting on the pipeline...
Страница 69: ...miniELCOR 62 Fig 30 Shielding connection in bushing 12 35...
Страница 84: ...miniELCOR 77 Fig 33 Base device parameters Fig 34 Data archive...
Страница 100: ...miniELCOR 93 Fig 50 Wizard for mathematical expression Fig 51 Equation for primary volume pulses and output connection...
Страница 111: ...miniELCOR 104 Fig 64 Switch of communication protocol in the device...
Страница 114: ...miniELCOR 107 Fig 66 Fig 67...
Страница 119: ...miniELCOR 112 Fig 70 Fig 71...
Страница 120: ...miniELCOR 113 Fig 72 Fig 73...
Страница 121: ...miniELCOR 114 Fig 74 Fig 75...
Страница 122: ...miniELCOR 115 Fig 76...
Страница 125: ...miniELCOR 118...