17 Software settings of the device for proper
communication with external digital temperature
(EDT-34) or pressure transducer (EDT-23)
Chapter 5.3 describes how to extend device with pressure or temperature
digital transducer. Following software setting suppose already installed expansion
module RS-485 and also already connected digital transducer (EDT-34 or EDT-23).
Now we will describe how to add new digital transducer into software
parameters.
17.1 Adding of digital transducer into device’s parameters
As a first step it is necessary to readout parameters from the device (menu
Readout ->Parameters
).
Now click in parameters menu on „
miniElcor
“ item. Using right mouse button
open menu. In opened menu select „
Insert object
“ and in next selection choose
required transducer (e.g. temperature transducer EDT-34, see Fig. 69). Herewith we
have added digital transducer into parameters and now it is necessary to save
modified parameters into the device by clicking on „
Save into device
“ button.
Now click in parameters menu on just added digital transducer EDT-34 (see
Fig. 70). Because it is a digital transducer connected to intrinsically safe serial
interface RS-485 such device must have assigned communication address. There
can come two possibilities in context of assigning of communication adress:
a) New digital transducer has the same address as is predefined in
parameters – standartly it is address no. 1 (see chapter 17.1.1.).
b) New digital transducer has different address than is stored in device’s
parameters (see chapter 17.1.2).
17.1.1 Newly installed digital transducer has the same address as is
predefined in device’s parameters (standartly address no.1)
In this case it is not necessary to change communication address. By clicking
on „
Parameters of module
“ button (see Fig. 71) we will check if transducer is
communicating with the device. If everything is correct, window with transducer’s
parameters will appear (see Fig. 71). If service software will warn you, that „
Module
doesn’t respond
“ it means that the address of transducer is different from address
preset in parameters and it is required to set correct address. Setting of the correct
communication address will be described in chapter 17.1.2 .
If transducer communicate without any problem (parameters of the module
were readed correctly), installation is finished.
Note: After adding of digital transducer it is possible (if needed) to make one or
two point calibration of transducer. (see Fig. 72).
Содержание miniELCOR
Страница 13: ...miniELCOR 6 Fig 1 Volume and energy calculations Scheme...
Страница 19: ...miniELCOR 12 Fig 5 Security marks device without SCR encoder Fig 6 Security marks of miniELCOR SCR...
Страница 50: ...miniELCOR 43...
Страница 55: ...miniELCOR 48 Fig 22 Basic navigation from the initial screen FW 2 xx...
Страница 65: ...miniELCOR 58 Fig 26 Mounting of miniElcor to the mounting plate Fig 27 Mounting on the pipeline...
Страница 69: ...miniELCOR 62 Fig 30 Shielding connection in bushing 12 35...
Страница 84: ...miniELCOR 77 Fig 33 Base device parameters Fig 34 Data archive...
Страница 100: ...miniELCOR 93 Fig 50 Wizard for mathematical expression Fig 51 Equation for primary volume pulses and output connection...
Страница 111: ...miniELCOR 104 Fig 64 Switch of communication protocol in the device...
Страница 114: ...miniELCOR 107 Fig 66 Fig 67...
Страница 119: ...miniELCOR 112 Fig 70 Fig 71...
Страница 120: ...miniELCOR 113 Fig 72 Fig 73...
Страница 121: ...miniELCOR 114 Fig 74 Fig 75...
Страница 122: ...miniELCOR 115 Fig 76...
Страница 125: ...miniELCOR 118...