5.4 Mechanical Installation
The device is intended for mounting on a wall or on a pipe by means of a mounting plate. In
the case of pipe mounting, special holders can also be used instead of the standard
mounting plate.
The device is mounted on the mounting plate first. If a device pressure transducer is required
to be connected via a 3-way ball valve, the 3-way ball valve can also be placed on this
mounting plate. The mounting plate has been designed to be fitted with three-way valves
supplied by ELGAS. The equipped mounting plate can be attached by means of screws and
dowels to the wall, or by means of two clamps with locking devices on horizontal or vertical
piping.
ATTENTION!
The gas volume corrector is a legally controlled technical equipment that is subject
to government professional supervision.
The device may be installed by only a qualified person holding a certificate of
professional competence issued by a government body of labour safety
supervision.
A person meeting the above conditions must also hold a "Certificate of completion
of professional training" for the installation and operation of the given type of
equipment. Such certificate is usually issued by the device manufacturer or an
authorized partner on the basis of the training provided.
Failure to comply with these requirements gives rise to a risk of breach of warranty
conditions.
ATTENTION!
The ELCOR, ELCORplus gas volume corrector is classified under the Metrology
Act as being in the category of approved measuring instruments. Entities intending
to carry out the installation of approved measuring instruments in the Czech
Republic are obliged to submit an application for registration to the Czech
Metrology Institute; see § 19 of the Metrology Act.
ATTENTION!
The device is available in various models to be used in ZONE 1 or ZONE 0
environment. The model designated for ZONE 1 must not be used in ZONE 0
environment.
The device may be operated in ZONE 0 only on condition that the "II 1G"
category is indicated on data plate of the device in the ATEX label.
Before installing the device to ZONE 0, make sure that the "II 1G" category is
indicated in the ATEX label.
Содержание DATCOM
Страница 38: ...3 Technical Parameters 36 ...
Страница 45: ...5 Installation and Commissioning 43 5 1 2 ELCORplus corrector Fig 2 ELCORplus device dimensions ...
Страница 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Страница 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Страница 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Страница 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Страница 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Страница 139: ...7 Technical Description of the Device 137 Fig 65 Volume and energy calculations calculation scheme ...
Страница 159: ...10 Communication with the Device 157 packet ...
Страница 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Страница 175: ...12 Accessories 173 Fig 79 ELCOR example of use of external modules Fig 80 ELCOR example of use of external modules ...
Страница 211: ...Appendix 2 ELCORplus version for Zone 2 209 Fig 86 Block diagram ELCORplus for zone 2 with ext 230V power supply ...
Страница 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Страница 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Страница 216: ...Appendix 3 Compass Data Export 214 ...
Страница 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...