Function Description
158
11 Function Description
The device offers highly variable and user-configurable options for displaying of values and
storing the quantities. The user can decide which quantities to display as actual values and which
quantities should be stored in the archives.
11.1 Quantities Designation
The quantities are designated using the symbols shown in the table “Symbols and Terms” (see
page 1).
Quantities Designation
The designations of the metrological quantities in the single channel device do not include
an index (Index 1 or 2 is used with dual channel devices.)
For other quantities (non-metrological), index can be used to distinguish the quantities of
the same type.
User Designation of Quantities
This new feature allows the user to define customized designations of quantities. The
original quantities designation then serves as the default designation (shown in blue in the
utility program [43]). The quantities designation must be chosen in such a way as to
preserve the uniqueness of the designation. The uniqueness of the designation is checked
by the utility program.
The designation of metrological quantities can only be changed at ASC level.
The user-defined quantities designation is used for display purposes both in the device
and in the utility program and can be exported to be used in third-party software.
11.2 Actual Values
For the displayed quantities, the number of displayed digits, the units, and the displayed name
are user-customizable. If the measured quantity is in an error state, this state is indicated by the
asterisk at the last position in the quantity designation row.
Example of quantities that can be displayed as actual values:
Pressure p1, p2
Temperature t1, t2
Primary volume Vm1, Vm2
Substitute primary volume Vs1, Vs2
Corrected volume Vb1, Vb2
Substitute corrected volume Vbs1, Vbs2
Energy E1, E2
Primary flow rate Q1, Q2
Corrected flow rate Qb1, Qb2
Conversion factor C1, C2
Compressibility factor K1, K2
Device error
External power supply
Battery capacity
Internal temperature
Содержание DATCOM
Страница 38: ...3 Technical Parameters 36 ...
Страница 45: ...5 Installation and Commissioning 43 5 1 2 ELCORplus corrector Fig 2 ELCORplus device dimensions ...
Страница 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Страница 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Страница 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Страница 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Страница 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Страница 139: ...7 Technical Description of the Device 137 Fig 65 Volume and energy calculations calculation scheme ...
Страница 159: ...10 Communication with the Device 157 packet ...
Страница 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Страница 175: ...12 Accessories 173 Fig 79 ELCOR example of use of external modules Fig 80 ELCOR example of use of external modules ...
Страница 211: ...Appendix 2 ELCORplus version for Zone 2 209 Fig 86 Block diagram ELCORplus for zone 2 with ext 230V power supply ...
Страница 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Страница 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Страница 216: ...Appendix 3 Compass Data Export 214 ...
Страница 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...