7
Technical Description of the Device
108
7 Technical Description of the Device
WARNING!
All the connectors in the device contain a mechanical safety lock
1
against
accidental disconnection.
To disconnect the connector, first press the lock to release the connector,
then pull the connector gently out of the socket. Never apply force grasping
and pulling the cable, it can be damaged.
To re-connect the cable to the device, plug the connector slightly so that the
lock snaps into place, then check for the proper connection by a slight
pulling on the cable.
7.1 Architecture of the Device
The device is of compact design with a temperature and pressure transducers solidly attached. In
the standard version of the corrector, the pressure transducer is built into the bottom wall of the
enclosure. The device architecture is based on interchangeable modules that are mounted in the
slots of the I/O board (see below) located on the bottom of the enclosure.
The CPU Module (processor board) with the display, keypad, and battery for the device (powering
the device except the modem) is located in the top cover of the device. The CPU module is
protected by the cover and marked with an official mark. In the cover of the board is an opening to
access the service switch. Use the service switch to enable/disable the device parameter
settings.
At the bottom of the cabinet there is the I/O board of inputs and outputs with terminal blocks for
connecting external devices and with slot connectors for connecting of exchange modules used to
extend the features of the device.
Connections related to the metrological function of the corrector are protected by covers that are
marked with the official mark.
i
The device is equipped with autodetection of the installed modules.
Modules located in SLOT 0, SLOT 1, SLOT 2 and SLOT 3 are always detected
(without any other conditions).
To the detection of SLOT 4 and SLOT 5 modules, the following applies:
Modems requiring a modem battery (S4-PWR2 module or M2G, M4G
modem) can only be detected in these slots with the modem battery
connected.
Other modules are always detected.
Содержание DATCOM
Страница 38: ...3 Technical Parameters 36 ...
Страница 45: ...5 Installation and Commissioning 43 5 1 2 ELCORplus corrector Fig 2 ELCORplus device dimensions ...
Страница 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Страница 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Страница 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Страница 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Страница 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Страница 139: ...7 Technical Description of the Device 137 Fig 65 Volume and energy calculations calculation scheme ...
Страница 159: ...10 Communication with the Device 157 packet ...
Страница 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Страница 175: ...12 Accessories 173 Fig 79 ELCOR example of use of external modules Fig 80 ELCOR example of use of external modules ...
Страница 211: ...Appendix 2 ELCORplus version for Zone 2 209 Fig 86 Block diagram ELCORplus for zone 2 with ext 230V power supply ...
Страница 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Страница 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Страница 216: ...Appendix 3 Compass Data Export 214 ...
Страница 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...