background image

3.9 

Safety instructions on electrical installation 

 

Work on the electric system of the used equipment must 
only be carried out by authorized electricians according to 
applicable rules and regulations by the trade association, 
particularly the provisions of DIN VDE 0100. Additionally, 
the national legal regulations of the respective country of 
operation must be observed. 

 

In case of defects like loose connections or defective or 
damaged cables on the system, the product must not put 
into operation. 

 

Prior to any inspection, installation or disassembly work, 
the system (blinds, shutter) must be disconnected from 
the voltage. 

 

All electrical connections, safety equipment, safeguards 
etc. must be properly installed, connected and grounded. 

 

The power connection must be designed according to the 
information in the electrical circuit diagram (type and level 
of voltage). 

 

One circuit breaker is suf

fi

 cient to disconnect the system 

from the mains supply (if only one phase and neutral is 
used). 

 

If one 

fi

 xed (stationary installed) drive system is not 

equipped with a mains cable with plug or other means 
of disconnection from the mains supply with a contact 
opening width according to the provisions of overvoltage 
category II (according to IEC 60664-1) for full disconnect, 
an isolating device of this kind must be installed into the 

fi

 xed electrical installation according to the installation 

regulations. 

 

Mains connection cables for drive systems with rubber 
hose cables (code 60245 IEC 53) must always be repla-
ced by cables of the same type. 

 

The following applies for drive systems with access to 
unprotected, movable parts after installation: Movable 
parts of the drive system must be installed at least 2.5 m 
above the ground (or another level providing access to 
the drive system). 

4 Product 

description 

The RolTop-915 is a wireless-controlled electromechanical 
tubular motor drive. During operation it carries out radial 
movements. 

 

Commissioning of the RolTop-915 with 

elero

 installation 

cable or transmitter for con

fi

 guration of various functions. 

 

Fabric protection system with retraction 

 

Fabric relief function (Fabric protection system) 

Relief function and retraction for fabric protection are only 
active in wireless operation. 

•  The values for your RolTop-915 model can be found on 

the name plate. 

•  Depending on torque and size, the different models of the 

RolTop-915 are equipped with different types of braking 
systems. This may lead to different operating properties 
e. g. when approaching an end position. 

4 | US+CA 

© 

elero

 GmbH

 

Safety | Product description 

3.6 

Safety instructions on technical condition 

 

Prior to installation the product must be checked for 
damage and proper condition. 

 

The operator is obliged to only operate the product in 
technically 

fl

 awless and operationally safe condition. The 

technical condition must comply with statutory require-
ments applicable at the date of manufacturing stated on 
the name plate. 

 

If dangers for personnel or changes in the operational 
behavior are identi

fi

 ed, the product must be put out of 

operation immediately and the operator must be informed 
on the incident. 

 

Without approval by the manufacturer, no modi

fi

 cation, 

extensions or alterations must be carried out on the 
product. 

 

The system must be regularly checked for imbalance or 
signs of wear or damaged cables and springs (if appli-
cable). 

3.7 

Safety instructions on transport, 
assembly and installation 

In general, the respective transport company is responsible 
for transporting the product. The following safety require-
ments must be observed during transport, assembly and 
installation of the product: 

 

During transport, the product must be secured according 
to the regulations of the used means of transport. 

 

For transport, only hoisting equipment and suspension 
gear must be used that are appropriately dimensioned 
for safely handling the forces occurring during loading, 
unloading and assembly of the product. 

 

Only points de

fi

 ned for hoisting or suspension at the 

pallet and the product must be used for hoisting or sus-
pension. 

 

If work must be carried out under suspended parts or 
working equipment, these must be secured against falling 
by suitable means. It must be ensured by suitable hois-
ting equipment that loads drift unintentionally, fall or get 
unhooked unsupervised. 

 

Standing under suspended loads is forbidden. 

 

During loading with hoisting equipment, a safety helmet 
must be worn. 

 

Assembly and installation must generally only be carried 
out by trained and suitably instructed specialists. 

 

The rated torque and the rated operating time must be 
suitable for the properties of the driven component („fa-
bric“). 
Decisive for the determination of the drive system is the 
drive computation program of the manufacturer. 

 

The smallest internal tube diameter for the winding shaft 
is 36 mm for RolTop-915 type S, 47 mm for RolTop-915 
type M and 58 mm for RolTop-915 type L. 

 

Access to the drive system must be ensured by a freely 
accessible appropriately sized inspection 

fl

 ap that can 

easily be opened. 

3.8 

Safety instructions on operation 

 

Before initial commissioning, the operator is obliged to 
inspect the product for safe and proper operation. 

 

Inspections must also be carried out during operation of 
the product in regular intervals de

fi

 ned by the operator. 

Содержание RolTop-915

Страница 1: ... misuse 2 2 4 Warranty and liability 2 2 5 Customer service of the manufacturer 2 3 Safety 2 3 1 General safety instructions 2 3 2 Layout of safety instructions 2 3 3 General safety principles 3 3 4 General obligations of the operator 3 3 5 General requirements on personnel 3 3 6 Safety instructions on technical condition 4 3 7 Safety instructions on transport assembly and installation 4 3 8 Safet...

Страница 2: ...t from the safety instructions in these operating instructions applicable local regulations on pre vention of accidents environmental protection and occupa tional safety must be observed Regulations and standards for safety assessment can be found in the EC Declaration of Conformity 2 2 Intended use This product is intended for use in facade construction for driving electrical sun protection devic...

Страница 3: ... in the country of operation and other binding regulations on ope rational safety prevention of accidents and environmental protection are complied with All work on the product must only performed by trained safety related instructed and authorized personnel Appropriately qualified personnel must observe all appli cable standards and regulations in the country of installation and inform the custom...

Страница 4: ... Product description 3 6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition The operator is obliged to only operate the product in technically flawless and operationally safe condition The technical condition must comply with statutory require ments applicable at the date of manufacturing stated on the name plate If dangers ...

Страница 5: ...iately after removing the Rol Top 915 from its original packaging The drive system must be installed in a position safe from rain Important On delivery factory settings the RolTop 915 is in commis sioning mode It is necessary to set the end positions refer to section 5 6 Optimum use of the wireless signal Position the antenna as freely as possible and reposition it in case of bad reception Do not ...

Страница 6: ... initial commissioning check the correct connec tion of the PE conductor NOTE Damage to the RolTop 915 due to incorrect electrical con nection Before initial commissioning check the correct connec tion of the PE conductor Damage to or destruction of the RolTop 915 due to ingress of humidity For devices with protection class IP44 the customer provided connection of cables or plugs wiring must also ...

Страница 7: ...n D refer to section 5 6 9 Activating the relief function at the lower limit stop 1 In a medium fabric position using the installation cable or a programmed transmitter keep the DOWN button pressed from step section 5 6 8 and 5 6 9 and press additionally simultaneously the UPbutton Keep both buttons pressed until the fabric stops The relief function at the lower limit stop is activated 5 6 4 Chang...

Страница 8: ...omatically The lower end position is set Optional Activation of the relief function for the lower limit stop refer to section 5 6 3 End position setting of option D is completed Fig 12 End position setting option D 8 US CA elero GmbH End position settings 5 6 7 Option A Upper and lower end position freely configurable Option A Upper and lower end position freely configurable In a medium fabric pos...

Страница 9: ...ric stops briefly moves on stops and moves downwards 5 On the additionally transmitter to be program med immediately max 1 second after start of a down movement press the DOWNbutton The status indicator flashes briefly The drive system stops Programming of the additional transmitter is complete Stopping the bidirectional wireless programming mode Press the STOP button for at least 6 seconds until ...

Страница 10: ...en Produktbezeichnung Rohrmotor RolTop S 915 120V 60Hz alle Varianten RolTop M 915 120V 60Hz alle Varianten Beschreibung Einsteckantrieb für Rollläden mit 915 MHz Funkempfänger Die Übereinstimmung der s bezeichneten Produkte s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen berücksichtigt R TTE Richtlinie 1999 5 EG Niederspannungsrichtlinie 2006 95 E...

Отзывы: