background image

5 Installation 

CAUTION 

Risk of injury due to hot surfaces. 

The drive system gets hot during operation, therefore the 
housing may be hot. Risk of skin burns. 

 

Wear personal protective equipment (protective gloves). 

Due to potential material defects, a broken gear unit, drive 
or coupling defect may cause injuries from impacts or 
shocks. 

 

For design of the system, suitable materials were used 
and a sampling test in form of a double load test accor-
ding to DIN EN 60335-2-97 was carried out. 

Risk of injury from impacts or shocks due to incorrectly 
installed or not properly engaged motor bearings. Risk due 
to insufficient stability and stored energy (gravity). 

 

Selection of motor bearings according to torque speci

fi

 -

cations. 

 

The drive system must be secured with all provided 
safety equipment. 

 

Inspection for proper engagement on the motor bearing 
and correct screw tightening torques. 

WARNING 

Risk of injury due to electricity. 

Risk of electric shock. 

 

Electrical work must only be carried out by authorized 
electricians. 

Risk of injury due to electricity. 

Potential risk from parts that have become live due to a 
malfunction. 

 

The electrical connection including wiring is described in 
the operating and installation instructions. 

CAUTION 

Risk of injury due to malfunctions due to incorrect installa-
tion. 

Excessive winding of the drive system leads to possible 
destruction of system parts. 

 

For safe operation, end positions must be set / program-
med. 

 

Training courses by the manufacturer for specialized 
companies. 

NOTE 

Power supply failure, braking of machine components and 
other defects. 

 

For safe operation, the system must be properly installed 
and the end positions must be set on commissioning. 

Damage to the RolTop-915 by humidity ingress. 

 

On protection class IP44 systems, all cables or plugs 
must be protected against ingress of humidity. This ac-
tion must be taken immediately after removing the Rol-
Top-915 from its original packaging. 

 

The drive system must be installed in a position safe from 
rain. 

Important 

On delivery (factory settings), the RolTop-915 is in commis-
sioning mode. 

 

It is necessary to set the end positions 
(refer to section 5.6). 

Optimum use of the wireless signal. 

 

Position the antenna as freely as possible and reposition 
it in case of bad reception. 

 

Do not bend, shorten or extent the antenna. 

 

Observe the minimum distance between two wireless 
drive systems of 15 cm. 

5.1 Mechanical 

mounting 

Important preliminary consideration: 

The working space around the installed drive system is 
often limited. Therefore, get an overview of the implementa-
tion of the electrical connection (refer to section 5.2) prior to 
the mechanical installation and carry out respective chan-
ges, if necessary. 

NOTE 

Damage to electrical lines by pressure or tensile loads. 

 

All electrical lines must be laid safe from pressure or 
tensile loads. 

 

Observe the bending radius of the cables (at least 50 
mm). 

 

Lay connection cables in a loop downwards to prevent 
water from running into the system. 

Damage to the drive system by impact loads. 

 

Always slide the drive system onto the shaft. Never ham-
mer onto the shaft or the drive system! 

 

Never drop the drive system! 

Damage to or destruction of the drive system by drilling. 

 

Never drill into the drive system! 

Important 

Attach the RolTop-915 only to the provided mounting ele-

ments. 

Firmly mounted control units must be visible attached. 

•  The fabric must be mounted on the winding shaft. 

• The pro

fi

 le tube must have suf

fi

 cient clearance to the 

motor tube. 

•  Make sure there is suf

fi

 cient axial play (1 - 2 mm). 

Installation in pro

fi

 le tubes

 

Ⓐ Push the drive with suitable adapter 

and driving collar into the profile tube.

 

Protect the motor cable in order to 
avoid damage from the driven com-
ponent. 

Ⓑ Secure the counterbearings to pre-

vent axial movement, e. g. screw or 

rivet on shaft carrier.

 

Axially secure the drive in the bea-
ring! 

Ⓒ Attach the fabric to the shaft!

 

B

A

C

 

© 

elero

 GmbH  

US+CA | 5

Installation | Mechanical mounting 

Содержание RolTop-915

Страница 1: ... misuse 2 2 4 Warranty and liability 2 2 5 Customer service of the manufacturer 2 3 Safety 2 3 1 General safety instructions 2 3 2 Layout of safety instructions 2 3 3 General safety principles 3 3 4 General obligations of the operator 3 3 5 General requirements on personnel 3 3 6 Safety instructions on technical condition 4 3 7 Safety instructions on transport assembly and installation 4 3 8 Safet...

Страница 2: ...t from the safety instructions in these operating instructions applicable local regulations on pre vention of accidents environmental protection and occupa tional safety must be observed Regulations and standards for safety assessment can be found in the EC Declaration of Conformity 2 2 Intended use This product is intended for use in facade construction for driving electrical sun protection devic...

Страница 3: ... in the country of operation and other binding regulations on ope rational safety prevention of accidents and environmental protection are complied with All work on the product must only performed by trained safety related instructed and authorized personnel Appropriately qualified personnel must observe all appli cable standards and regulations in the country of installation and inform the custom...

Страница 4: ... Product description 3 6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition The operator is obliged to only operate the product in technically flawless and operationally safe condition The technical condition must comply with statutory require ments applicable at the date of manufacturing stated on the name plate If dangers ...

Страница 5: ...iately after removing the Rol Top 915 from its original packaging The drive system must be installed in a position safe from rain Important On delivery factory settings the RolTop 915 is in commis sioning mode It is necessary to set the end positions refer to section 5 6 Optimum use of the wireless signal Position the antenna as freely as possible and reposition it in case of bad reception Do not ...

Страница 6: ... initial commissioning check the correct connec tion of the PE conductor NOTE Damage to the RolTop 915 due to incorrect electrical con nection Before initial commissioning check the correct connec tion of the PE conductor Damage to or destruction of the RolTop 915 due to ingress of humidity For devices with protection class IP44 the customer provided connection of cables or plugs wiring must also ...

Страница 7: ...n D refer to section 5 6 9 Activating the relief function at the lower limit stop 1 In a medium fabric position using the installation cable or a programmed transmitter keep the DOWN button pressed from step section 5 6 8 and 5 6 9 and press additionally simultaneously the UPbutton Keep both buttons pressed until the fabric stops The relief function at the lower limit stop is activated 5 6 4 Chang...

Страница 8: ...omatically The lower end position is set Optional Activation of the relief function for the lower limit stop refer to section 5 6 3 End position setting of option D is completed Fig 12 End position setting option D 8 US CA elero GmbH End position settings 5 6 7 Option A Upper and lower end position freely configurable Option A Upper and lower end position freely configurable In a medium fabric pos...

Страница 9: ...ric stops briefly moves on stops and moves downwards 5 On the additionally transmitter to be program med immediately max 1 second after start of a down movement press the DOWNbutton The status indicator flashes briefly The drive system stops Programming of the additional transmitter is complete Stopping the bidirectional wireless programming mode Press the STOP button for at least 6 seconds until ...

Страница 10: ...en Produktbezeichnung Rohrmotor RolTop S 915 120V 60Hz alle Varianten RolTop M 915 120V 60Hz alle Varianten Beschreibung Einsteckantrieb für Rollläden mit 915 MHz Funkempfänger Die Übereinstimmung der s bezeichneten Produkte s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen berücksichtigt R TTE Richtlinie 1999 5 EG Niederspannungsrichtlinie 2006 95 E...

Отзывы: