3.4
Manual operation
3.4.1
Switching on the device
The device should, as far as possible, always be switched on using the rotary switch on the front of the device. Alternatively
this can take place using an external cutout (contactor, circuit breaker) of suitable current capacity.
After switching on, the display will first show some device related information (model, firmware versions etc.) and then a
language selection screen for 3 seconds. A few seconds later it will show the main screen.
In the
Settings
menu (also see section
“3.4.3. Configuration via the menu“
) in the group
DC output
is an option
State after
power ON
in which the user can determine the condition of the DC power stages after power-up. Factory setting here is
Off
,
meaning that the DC power stage on power-up are always switched off.
Restore
means that the last condition will be restored,
either on or off. All set values are always saved and restored.
For the time of the start phase the analog interface can signal undefined statuses on its digital outputs.
This must be ignored until the device has finished booting and is ready to work.
While manually operated and while also being connected to any remote control equipment via any of
the interfaces, the device could be taken over into remote control anytime without warning or request
for confirmation. It’s thus recommended to block remote control by activating the ‘Local’ mode for the
duration of manual operation.
3.4.2
Switching the device off
On switch-off the last output condition and the most recent set values are saved. Furthermore, a PF alarm (power failure)
will be reported, but can be ignored.
The DC output is immediately switched off and after a short while fans will shut down and after another few seconds the
device will be completely powered off.
3.4.3
Configuration via the menu
The settings menu is meant for the configuration of all operating param
-
eters which are not constantly required. The menu is accessed by finger
touch on the
Menu
touch area, but only while the DC output is switched
off. See figure to the right.
While the DC output is switched on the settings menu will not be shown,
but some status information.
Menu navigation is also done by finger touch. Inside menus, all values
are adjusted using the numeric pad that pops up when tapping a value.
Many settings are self-explanatory, others are not. Those will be explained
on the pages following.