24
5- Press the Coin Return Push Button.
8. INSTALLATION and CLEANING
Maxi-Buffet
®
is designed to operate
7/24 basis. The Maxi-Buffet can be operated only
after proceeding necessary steps described in the User’s Manual.
Do not use water directly to clean the Machine. Use dry or damp cloth for cleaning.
Electronic units should be protected from water.
During product loading and cash collection, the Vending Machine will be opened often and
may result in “Errors” which can be checked from the menu and necessary corrections have
to be made as soon as possible.
Unauthorized staff must not maintain the equipment. Whilst in maintenance, proceed as per
“Service Manual” instructions.
Important Warnings
•
When pulling the trays out, make sure the front door is open at a 120° angle.
Otherwise the Tray may hit the door or rubber front door gasket and can cause
damage.
•
Gently hold the tray upwards before pulling it out.
•
When the tray is in loading position the inner steps of the spirals have to be loaded
first and the trays have to be pushed back in place while loading the products to the
front lines. Overloading the tray in loading position may result in damages and the
tray may slide out from its place causing injuries, cable failures or other physical
damages.
•
The Cooling Unit should be serviced every year and the Cooling Unit Condenser
should be cleaned.
9. OPTIONAL UNITS
9.1 Cooling Unit
The Maxi Buffet has an Optional Modular Cooling unit for
vending refrigerated Cold Drinks and/or snack foods. It has a
high cooling capacity of 600 W Cooling Power. The modular
Cooling Units and electronic thermostat controlled economy
mode operation are some of its features. The Cooling Unit has
a complete modular design enabling ease of assembly and
maintenance. Modular Cooling Unit can be equipped to a
Standard Maxi-Buffet at a later time as an optional unit.
The compressor and the fans operate with 210-240 V, 50 Hz.
Non-inflammable and non-exploding gas R134-A has been used in the system. As a
protection measure the compressor starts operating 2.5 minutes after the power on.
Evaporator, condenser and defrost system are other features of the cooling module.
Compressor Features:
Hermetic Reciprocating, HBP(+7,2°C / 54,4°C), H. Power: 3/8, Cooling Capacity: 1.316 W
Motor Type: 1 Phase – RSIR, cm3/rev: 11,14
Suction Line: 5/16” Discharge Line: 1/4”