15 TROUBLE SHOOTING
15.1 CONVEYOR
CLUTCH
SYMPTOM POSSIBLE
CAUSE(S)
REMEDY(S)
The conveyor clutch (torque
limiter) tripped. Part jammed in
Roto-Flo bearing.
Check the entire length of the
Roto-Flo conveyor for any jams
or pinching. Correct any jams or
pinch points.
Main Conveyor Clutch is tripped.
A Roto-Flo conveyor bearing is
binding on the conveyor causing
excessive torque.
Repair reason for binding or
replace with new bearing. Re-set
Clutch.
15.2 BAD
PART
BAD PART - SYMPTOM
POSSIBLE CAUSE(S)
REMEDY(S)
Pump not running
Check electrical connection
Hose clogged
Check for blocked tip, clear clog
or replace hose.
Lines not in Resin
Make sure hoses are below the
resin level.
No Resin on part
Holding Tank empty
Note: blue light will come “ON”
to indicate tank is empty
Fill Holding Tank with resin.
Note: blue light will turn “OFF”
Resin flow rate set too low
Turn flow rate up.
Low part temperature
Turn Induction Heater setting up.
Partial Resin coating
Nozzles mis-aligned with part
Re-align Nozzles (move photo
eye).
Содержание 18028