6.4 CURE
MODULE
The Cure Module, located just after the Trickle Station, allows time for the resin on
each part to cure. The insulated hood should always be in place while the machine is
running, to retain the heat.
6.5
FINAL COOL MODULE
In this module the part passes through an aerodynamically designed directional vane,
directing air around each coated part. The air is moved using a rotor type exhausting
fan. When the part leaves this module, it is cool enough to be handled by hand.
6.6 AIR
FILTERS
A Particle Air Filter and a Coalescing Air Filter are installed at the main air supply
drop for the System (the main air drop is located behind the machine at the Cure
Module). These filters are provided to remove foreign particles and oil from the air
entering the System.
For specific information on the Particle Filter and Coalescing Filter, refer to the
Manufacturer's Manuals Section of this Manual.
6.7
FIRE EXTINGUISHER SYSTEM
A separate free-standing Fire Extinguisher System provided to spray CO² (Carbon
Dioxide) in various stations on the machine in the case of fire. The unit (and
Operating Controls) is located behind the machine in the Cure Section.
There are two (2) Heat Sensors and four (4) spray nozzles located in the Trickle
Station; one (1) Heat Sensor and two (2) spray nozzles located in the Cure Tunnel
and one (1) Heat Sensor and one (1) spray nozzle located in the Final Cool Exhaust
Duct.
The CO² (Carbon Dioxide) system is discharged when a Heat Sensor senses the
temperature in a Section of the System has exceeded the pre-set temperature setting
on that Heat Sensor. The Sensor in the Trickle Station has been set for 450° F; the
Sensor in the Cure Tunnel has been set for 600° F; and the Sensor in the Final Cool
Exhaust Duct has been set for 600° F.
In the event that a Heat Sensor senses a fire condition: an Alarm Horn/Strobe Light
is energized; the exhaust air is shut down; the Trickle Impregnation Machine is shut
down; and the CO² (Carbon Dioxide) system is discharged.
NOTE
: if the CO² (Carbon Dioxide) system is discharged, the METRON
PROTRACTOR in the Electric Actuator
MUST
be replaced
Please refer to the Fire Control Service/ANSUL information in the Appendix of this
Manual for information on the Fire Extinguisher System.