MACHINE START-UP SCREEN
The MACHINE - SYSTEM START-UP SCREEN includes the following screen
buttons along with selections to access different screens and silence the audible
alarm:
SELECT AUTO MODE
Screen Pushbutton
Set the machine for Automatic operation.
SELECT MANUAL MODE
Screen Pushbutton
Set the machine for Manual operation.
MACHINE SYSTEM START
Screen Pushbutton
Starts the Induction Heater Water Pump and
Part Cooling Blower (also used to exhaust
the machine fumes).
MACHINE SYSTEM STOP
Screen Pushbutton
Stops the Induction Heater Water Pump and
Part Cooling Blower.
IND. HEATER SUPPLY POWER ON
Screen Pushbutton
Supplies Main Electrical Power to the
Induction Heater Cabinet.
IND. HEATER SUPPLY POWER OFF
Screen Pushbutton
Removes Main Electrical Power from the
Induction Heater Cabinet.
INDUCTION HEATER START
Screen Pushbutton
Starts on the Induction Heater, placing it in
Ready Mode providing no Induction Heater
faults exists.
Note
: The Induction Heater faults must be
cleared before it can be started. Press the
“IND. HTR. FAULT” screen pushbutton to
reset the Induction Heaters.
INDUCTION HEATER STOP
Screen Pushbutton
Stops the Induction Heater.
OVEN HEATERS ON
Screen Pushbutton
Supplies Electrical Power to the Oven
Heaters Control Circuit.
OVEN HEATERS OFF
Screen Pushbutton
Removes Electrical Power from the Oven
Heaters Control Circuit.
IND. HTR. FAULT RESET
Screen Pushbutton
Resets the Induction Heater cabinet.