CH 22
HSV 22
0
0
C z 55 C
0
0
C z 45 C
3
59
BLOWER POW. 30%
0
C
2. Application
Controller is equipped with innovative, intelligent Logic control system.
This system consists in automatic adjustment of boiler power to current
operating conditions. All regulation process is based on measurement of
central heating temperature. Due to innovative solution enabling optimal
fuel combustion in the boiler, it has the effect of reduction of harmful oxides
emission into the atmosphere. With proper oxides aftercombustion and no
overshoots , boiler equipped with our device can use up to 30% less fuel
than standard solutions.
3. Controller operation
To start up the controller hold ENTER button. After controller start up, main
page with following information is displayed on LCD:
Central heating (CH) temperatures
- current and set up
Hot service water (HSW) temperatures
- current and set
From the main page you have the access to several functions, pressing
( ) enters into central heating temperature adjusting mode, you set up
desired temperature with ( ) and ( ). When temperature decreases below
o
35 C (--) and ENTER button is pressed, central heating pump turns off.
Controller enters SUMMER MODE, with only hot service water function.
However, if ( ) is pressed as first, you enter into setting up hot service
water temperature. By pressing ( ) and ( ) you set up desired temperature.
o
When temperature decreases below 35 C (--) and ENTER button is pressed,
hot service water pump turns off.
Caution!!!
If installation is not equipped wit hot service water pump
you should turn off water heating function.
Pressing ENTER button confirms selected parameter and pressing EXIT
button exits without saving previously made changes.
CH Temperature
Blower power
SP 16 Manual