- PUMP START UP TEMPERATURE

  temperature at which circulation pomp starts up is 

o

o

  PLYNNIE adjustable within the range 30  - 5  C 
  below temperature set up for the boiler, i.e. CH 

o

  temperature is set up for 60 C, then range of

o

o

  pump regulation may be set between 30 C and 55 C.

- CH PRIORITY

 in this mode pumps start working 

  when boiler temperature reaches temperature set 
  up in pump start up function. (CH pump works
  permanently and HSW pump turns on after reaching desired temperature.)
  In this mode HSW temperature cannot be higher than CH temperature.  

- HSW hysteresis

 that function is to set up service 

  water hysteresis, it consists in delaying HSW
  pump start up by set up number of degrees, i.e. 

o

o

  hystheresis 2 , set up temperature 50 C - pump 
  shall start up when service water temperature 

o

  decreases to 48 C. This function works in HSW priority and summer mode. 

4

PUMP START TEMP.

PUMP START TEMP.

0

                  35 c

FUNCTIONS

- MANUAL OPERATION

 function is to fire up the 

  boiler, it enables independent start up of controller 
  and blower outputs.

Pressing ENTER button turns on one of the outputs. With (   ) and (   ) you 
change output to be turned on or off. Pressing EXIT returns to set up menu.

- CH/HSW PRIORITY

- HSW PRIORITY

 HSW pump starts up and works 

  until achieves set up temperature. When services 
  water reaches set up temperature HSW pump
  turns off and CH pump turns on.

SP 16 Manual                                                              

Manual operation

Blower

2

0

C

HSW hysteresis

Hysteresis temp.
HSW

CH/HSW Prority

HSW Prority

CH Prority

Содержание Logic SP-16

Страница 1: ...16 MICROPROCESSOR TEMPERATURE CONTROLLER FOR CENTRAL HEATING BOILERS AND HOT SERVICE WATER BOILERS ...

Страница 2: ...with marked functions 1 Turning on hold ENTER button for 2 sec 2 LCD display 3 Indicator lights 4 Device control buttons 5 Blower start up indicator 6 Central heating pump start up indicator 7 Hot service water pump start up indicator 8 3 15 A fuse SP 16 Manual ...

Страница 3: ...yed on LCD Central heating CH temperatures current and set up Hot service water HSW temperatures current and set From the main page you have the access to several functions pressing enters into central heating temperature adjusting mode you set up desired temperature with and When temperature decreases below o 35 C and ENTER button is pressed central heating pump turns off Controller enters SUMMER...

Страница 4: ...n delaying HSW pump start up by set up number of degrees i e o o hystheresis 2 set up temperature 50 C pump shall start up when service water temperature o decreases to 48 C This function works in HSW priority and summer mode 4 PUMP START TEMP PUMP START TEMP 0 35 c FUNCTIONS MANUAL OPERATION function is to fire up the boiler it enables independent start up of controller and blower outputs Pressin...

Страница 5: ...mber that all personal settings will be lost END OF WORK turns the controller off To turn It on again press and hold ENTER button Controller has got hidden installation menu to get there press and hold and buttons for 3 seconds Changes of parameters in that menu should be made by qualified person Your changes of those parameters may cause controller misoperation INSTALLATION MENU TURN OFF TIME fun...

Страница 6: ... humidity 95 7 I insulation class 8 3 15 A fuse 9 Controller has got function preventing from premature freezing of o installation in case of temperature decrease below 6 C circulation pump starts up automatically 10 Controller is equipped with secondary protection emergency thermostat which protects the boiler against overheating 5 Use 1 Connect feeder of CH and HSW pump a yellow green conductor ...

Страница 7: ...alled and operated in accordance with rules of operating electrical devices Controller must not be exposed to water or to conditions causing steam condensation i e rapid changes of ambient temperature 5 In cases of controller misoperation first check a the fuse b connections stability and technical condition of cooperating devices that means the blower pumps c Set the controller to manufacturer se...

Страница 8: ...ice centre 7 Seller is obliged to fill in the warranty card on the day of giving out the equipment Warranty card which is not filled in or having any corrections or cross outs precludes exercising warranty rights Information on utilization of electric and electronic devices This symbol placed on products or documentation attached to them informs that unserviceable electric or electronic devices mu...

Страница 9: ...9 Notatki ...

Страница 10: ...10 Notatki ...

Страница 11: ...11 Data sprzeda y Podpis Piecz tka punktu sprzeda y Data Zakres reklamacji Podpis i pieczatka Warranty card ...

Страница 12: ...ul Moczyd o 10a 30 698 Kraków tel 012 650 47 90 fax 012 650 47 91 e mail biuro electronics net pl Producent Zak ad Elektroniczny Electronics Tadeusz Wilgocki ...

Отзывы: