Pag. 39
SIRIO 2000T
SIRIO 2000T
SIRIO 2000T
SIRIO 2000T
SIRIO 2000T
Electronic Broadcast Equipment
Menu #29: Date and Time Set
This field is the command mode display of menu #09 with the 2nd level password authorisation and allows
to set date and time.
As in the previous menu, the left and right keys change the input fields while the up and down keys
increase/decrease now the date and time.
Menu #31: Maximum Reflected Power Set
This field permits to set the maximum reflected power level. Default value is nearly 90W and in any case
this power is hardware limited to 100/120W for security reason.
Auto Control on the lower line is not yet operative and could be absent in some software release.
Menu #32: Limiter Set
This field, with the 2nd level authorisation, permits to set the limiter action. The right/left keys toggle the
limiter on and off. The up/down keys vary the threshold level.
Auto Control on the lower line is not operative in some software release. When it is, it will dynamically
reduce the input sensitivity to allow distorsionless limiting if pre-set to ON. Even in this case it will be wise
not to exceed the limiter threshold to avoid a "pumping" effect on the modulation.
Refl.Pw limit 87 W
Auto Control OFF
T(A/H): +30°C +36°C
01 JAN 02 17:22:10
MPX limit + 7.1dB
Auto Control OFF