![background image](http://html.mh-extra.com/html/electrolux/smart-promix/smart-promix_service-manual_90731007.webp)
7
Electronic
Valid from Rev. UCP 0426 to UCP 0427
Replacement of effect PCB
(se fig.1)
When replacing the effect PCB, the electronic shall be adjusted
for the correct size boiling pan as below:
· Press Menu forwards
and Menu back
simultaneously
for 5 seconds.
· Digit the code 1991 by pressing Increase value
or De-
crease value
for digits, and Menu forwards
or Menu
back
for the position.
· Confirm by pressing Start
.
PARAMETER SET-UP
· Press Menu forwards
INITIATE PROGRAM
NO
YES
· Press Decrease value
for ”YES” (If the the PCB-board
shall be programmed for the first time, YES option has to
be selected).
· Press Menu forwards
· Confirm by pressing Start
The process will take a few minutes.
· Press Menu forwards
INITIATE DEFAULT
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
· Confirm by pressing Start
· Press Menu forwards
SIZE
50
· Select boiling pan SIZE pressing Increase value
or De-
crease value
· Press Menu forwards
AGITATOR
· Select VARIOMIX/PROMIX or WITHOUT AGITATOR
(Smart) pressing Increase value
or Decrease value
· Press Menu forwards
FOOD TEMP
NO
YES
· Select between YES or NO
· Press Menu forwards
FLOW METER
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
PULSE/ LITRE
· Select PULSE/ LITRE (428 or 495 pulse/ litre*)
· Press Increase value
or Decrease value
.
* Check the current value on the flow meter.
· Press Menu forwards
AUTOMATIC COOLING
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
If "YES" is chosen:
ICE WATER COOLING
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
OPTION
· Select WITHOUT HACCP or WITH HACCP pressing
Increase value
or Decrease value
LANGUAGE
· Select
LANGUAGE pressing Increase value
or Decrease
value
· Press Menu forwards
To change the language, se even the section for Choice of
language at page 5.
PROGRAMMING
NO
YES
· Press Decrease value
for ”YES”
· End the process by switching off the power, pressing ON/
OFF
.
Fuses:
there are 2 fuses on the effect PCB as follows:
F1= 400 mA Delay action fuse (5X20mm)
F2= 315 mA Delay action fuse (5X20mm)