Calibration of temperature sensor
NOTE! In case of replacement of effect- or display PCB, the
food temperature sensor or the heating element temperature
sensor, temerature values for food and heating elemet have to
be calibrated as follows:
1. Fill up the boiling pan with appr. 10 cm water.
· Press Menu forwards
and Menu back
simultaneously
for 5 seconds.
· Digit the code 1122 by pressing Increase value
or De-
crease value
for digits, and Menu forwards
or Menu
back
for the position.
· Confirm by pressing Start
.
SAFETY TEST MODE
· Select SERVICE MODE, pressing Decrease value
and
press Menu forwards
twice.
SERVICE
JACKET TEMP
XX°C
CALIBRATED
X°C
2. Press Decrease value
and adjust the heating element
temperature sensor at -8°C.
3. Press Menu back
.
SERVICE
FOOD TEMP
XX°C
CALIBRATED
X°C
· Press Decrease value
and adjust the food temperature
sensor at -3°C.
4. Press Start
.
· Stir the water inside the pan with a wooden ladle.
· Boiling process starts. When the water inside the pan is
boiling, the display shall indicate 100°C. Calibrate the value
by pressing Increase value
or Decrease value
max.
±8°C.
· Press Stop
.
· Press Menu forwards
once and Press Start
.
· The boiling pan`s manometer have to show appr. 100-110
kPa (1,0-1,1 bar) when the display indicates 121°C. Calibrate
the value by pressing Increase value
or Decrease value
max ±8°C.
·
Press Stop
.
· End the process by switching off the power, pressing ON/
OFF
.
Radiator filler neck
Adjustment of the jacket cooling water
Valid to
june
2013.
1. Start the automatic cooling program, vait until a uniform
flow of water running out of both pipes.
2. Put a bucket under båth pipes and fill under 20 seconds.
3. messure the water and confer with the tabe below:
Size(L)
Flow (l/min.)
Flow (l/20 sec.)
50-100
10
3,3
150
11
3,7
200-300
12
4
Adjust with radiator filler neck.
Reset the service intervall
Resetting the service interval after completion of service in
order to change the message in the display.
•
Press Menu forwards
and Menu back
simultaneously
for 5 seconds.
•
Digit the code 1122 by pressing Increase value
or De-
crease value
for digits, and Menu forwards
or Menu
back
for the position.
· Confirm by pressing Start
.
• Select SERVICE MODE, pressing Decrease value
and
press Menu forwards
.
TIME TO SERVICE
0000 (0000) H
The time shown is the number of hours which elapsed since
the latest service and the maintenance interval.
• To reset the counter, press Stop
in 3 sec.
• End the process by switching off the power, pressing ON/