![Electrolux Smart Promix Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/electrolux/smart-promix/smart-promix_service-manual_90731008.webp)
8
Electronic
Valid from Rev. UCP 0428
Replacement of effect PCB
(se fig.1)
When replacing the effect PCB, the electronic shall be adjusted
for the correct size boiling pan as below:
· Press Menu forwards
and Menu back
simultaneously
for 5 seconds.
· Digit the code 1991 by pressing Increase value
or De-
crease value
for digits, and Menu forwards
or Menu
back
for the position.
· Confirm by pressing Start
.
PARAMETER SET-UP
· Press Menu forwards
INITIATE PROGRAM
NO
YES
· Press Decrease value
for ”YES” (If the the PCB-board
shall be programmed for the first time, YES option has to
be selected).
· Press Menu forwards
· Confirm by pressing Start
The process will take a few minutes.
· Press Menu forwards
INITIATE DEFAULT
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
· Confirm by pressing Start
· Press Menu forwards
SIZE
50
· Select boiling pan SIZE pressing Increase value
or De-
crease value
· Press Menu forwards
AGITATOR
· Select VARIOMIX/PROMIX or WITHOUT AGITATOR
(Smart) pressing Increase value
or Decrease value
· Press Menu forwards
FOOD TEMP
NO
YES
· Select between YES or NO
· Press Menu forwards
FLOW METER
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
PULSE/ LITRE
· Select PULSE/ LITRE (428 or 495 pulse/ litre*)
· Press Increase value
or Decrease value
.
* Check the current value on the flow meter.
· Press Menu forwards
AUTOMATIC COOLING
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
If "YES" is chosen:
ICE WATER COOLING
NO
YES
· Press Decrease value
for ”YES”
· Press Menu forwards
OPTION
· Select WITHOUT HACCP or WITH HACCP pressing
Increase value
or Decrease value
LANGUAGE
· Select
LANGUAGE pressing Increase value
or Decrease
value
· Press Menu forwards
To change the language, se even the section for Choice of
language at page 5.
PROGRAMMING
NO
YES
· Press Decrease value
for ”YES”
· End the process by switching off the power, pressing ON/
OFF
.
To insert maintenance interval
SERVICE INTERVAL
0600 H
· Press Increase value
to extend the interval
· Press Decrease value
to shorten the interval
000 H no service interval set.
Fuses:
there are 2 fuses on the effect PCB as follows:
F1= 400 mA Delay action fuse (5X20mm)
F2= 315 mA Delay action fuse (5X20mm)