![Electrolux Inspiration EWX11831 TC3 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/electrolux/inspiration-ewx11831-tc3/inspiration-ewx11831-tc3_service-manual_2385385009.webp)
Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
9/71
599 77 00-82 Rev. 01
4.3 Diagnostic test phases
Irrespective of the type of circuit board and the configuration of the selector, after entering the diagnostic
mode, turn the programme selector dial
clockwise
to perform the diagnostic cycle for the operation of the
various components and to read any alarms.
Concurrently a selector control code is shown on the LDC display for
two
seconds, before displaying what is
described in the last column of the table below.
(All alarms are enabled in the diagnostic cycle).
Selector
position
Components activated
Working conditions Function tested
LCD display
1
TC 3
-
The LEDs light up in
sequence, the symbols on the
LCD display light up in in
groups and the backlighting
comes on,
-
Touch a sensor to turn on the
group of icons in the LCD
screen or the corresponding
LED and the buzzer sounds at
the same time.
Always active
User interface
functioning
TC 4
2
TC 3
-
Door
safety
interlock
-
Wash
solenoid
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Water fill to wash
compartment
Water level in
the tub (mm)
TC 4
3
TC 3
-
Door
safety
interlock
-
Pre-wash
solenoid
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Water fill to
pre-wash
compartment
Water level in
the tub (mm)
TC 4
4
TC 3
-
Door
safety
interlock
-
Solenoid valve
pre-wash and wash
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Water fill to
conditioner
compartment
Water level in
the tub (mm)
TC 4