Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
11/71
599 77 00-82 Rev. 01
Selector
position
Components activated
Working conditions Function tested
LCD display
10
----- ----- -----
-----
-----
11
TC 3
-
Reading/Deleting
the
last alarm
-----
----
TC 4
12
÷
14
TC 3
-
The LEDs light up in
sequence, the symbols on the
LCD display light up in in
groups and the backlighting
comes on,
-
Touch a sensor to turn on the
group of icons in the LCD
screen or the corresponding
LED and the buzzer sounds at
the same time.
Always active
User interface
functioning
TC 4
(*)
In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining
the water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature is
higher than 80
C, heating does not take place).
(**)
The check at the maximum speed occurs without control of the A.G.S. and no garments must be inside the appliance
.