101
electroluxicon.com
Built-In All Freezer & All Refrigerator
Optional
Accessories
Single Louvered Trim Kit
TRIMKITSS1
For single unit installation.
Includes louvered top grille
and vented, louvered toe kick,
2-9/16" H leveling system
and side / top trim pieces.
Double Louvered Trim Kit
TRIMKITSS2
For double unit, side-by-
side installation. Includes
full-width, louvered top grille
and vented, louvered toe
kick, two 2-9/16" H leveling
systems, side / top trim pieces
and hardware to secure
side-by-side units together.
PureAdvantage
®
Air Filter Replacement
Cartridge
PN # EAFCBF
•
When installing freezer adjacent to wall, cabinet or
other appliance that extends beyond front edge of unit,
20" minimum clearance recommended to allow for
optimum 140° door swing, providing complete drawer /
crisper access and removal.
(Absolute 4" min. clearance
will ONLY allow for 90° door swing which will provide
limited drawer / crisper access with restricted removal.)
•
Freezer must be placed on level surface of hard
material, same height as flooring. Surface must support
approximately 800 lbs. when fully loaded. Unit equipped
with 4-point leveling.
“Built-In Look” Specifications
•
Minimum opening of 72" H x 33" W x 25-1/4" D required
for single-unit “Built-In Look” installation; 66" W required
for double-unit installation. (72" H to be measured from
finished floor to underside of soffit or overhead cabinet.)
•
Remove all wall / floor molding prior to built-in installation.
Optional Trim Kit Specifications
•
If optional Single or Double Louvered Trim Kit is to be
used, different cutout dimensions are required. Kits can be
adapted to fit either 75" or 79" opening height. (
Refer to
cutout dimensions on this page and detailed Louvered Trim
Kit installation instructions included with kit or on web.
)
•
Remove all wall / floor molding prior to built-in installation.
Installation Specifications
•
Product Weight – 237 Lbs.
•
An electrical supply with grounded three-prong receptacle
is required. The power supply circuit must be installed
in accordance with current edition of
National Electrical
Code (NFPA 70)
and local codes & ordinances.
•
Voltage Rating – 120V / 60 Hz / 20 Amps
•
Connected Load (kW Rating) @ 115 Volts = 0.55 kW
•
Amps @ 115 Volts = 5 Amps
•
Always consult local and national electric & plumbing
codes.
•
Water line for ice maker can enter opening through floor
or rear wall. Copper tubing recommended between cold
water line and water connection location. Water line tubing
recommended is 48" minimum length by 1/4" diameter.
Installation of easily accessible shutoff valve in water line
required.
•
Minimum 25-1/4" depth requires recessed electrical outlet
and copper water line.
•
To allow for ease of installation, tape excess power cord
to back of unit.
•
To allow for ease of moving out side-by-side units after
installation, 84" minimum length of coiled copper tubing
recommended.
planning
information
For model:
E32AF75JPS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
All Freezer
E32AF75JPS