Over-The-Range Microwaves
planning
information
For models:
E30MH65GPS
E30MH65GSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Installation drawing shown
with professional series model.
*Can NOT be installed
in island or peninsula
cabinet arrangements
16
3
/
8
"
29
7
/
8
"
14
3
/
8
"
Blower plate allows for vertical
or horizontal ducting
Power cord location
(right top rear)
16
7
/
8
"
1
/
2
" lower
extrusion
Allow at least 25
1
/
2
" clearance
for door depth when open
16
1
/
8
"
30"min.
33"max.
Backsplash
Rear Wall
16
1
/
2
"
min.
30"min.
69"min.
from floor
to top of
microwave
Bottom edge of
cabinet MUST be
33"min. from
cooking surface
Cabinet MUST
be capable of
supporting a total
load of 110 lbs.
30"
min.
Microwave MUST
be mounted to
BOTH a top cabinet
AND a wall*
Locate 120V/60Hz grounded outlet inside upper cabinet
12"
min.
5"min.
Optional
Accessories
36" Filler Panel Kit
PN # MWFILKTSS
•
Minimum distance of 33" required from cooking surface
to bottom edge of top cabinet.
•
Minimum distance of 69" required from floor to top of
microwave.
•
Opening between cabinets MUST be 30" wide and
free of obstructions.
•
Can only be installed over ranges or cooktops with
33" maximum width.
•
Allow 25-1/2" minimum clearance for 90° door swing.
Ducted Option Specifications
•
For outside ventilation.
•
Exhaust duct adapter supplied assembled for outside
ventilation, designed to mate with standard 3-1/4" x 10"
rectangular duct. If round duct required, rectangular-to-
round transition adapter will be needed with no less than
6" diameter.
•
For most efficient airflow exhaust, use a straight run or
as few elbows as possible with maximum duct length of
3-1/4" x 10" rectangular or 6" diameter round duct, not
to exceed 140 equivalent feet.
•
For horizontal installation, be sure to allow enough space
between wall studs to accommodate exhaust.
•
Refer to installation instructions on web for detailed duct
preparation and converting exhaust vent blower system
for exterior exhaust ventilation.
Installation Specifications
•
Product Weight – 75 Lbs.
•
Voltage Rating – 120V / 60 Hz / 20 Amp
•
Connected Load (kW Rating) @ 120 Volts = 1.6 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 14.5 Amps
•
Always consult local and national electric codes.
•
Grounded outlet should be located in cabinet above,
with hole in base to route power cord. Carefully follow
top template instructions for power cord clearance
when installing beneath smooth, flat cabinets.
•
Microwave’s ventilation system is preset to recirculate
air inside with no ducting system required. Exhausting
air outside is optional, using either vertical or horizontal
ducting system.
(Refer to Ducted Option Specifications
for outside ventilation.)
•
For safe and proper installation, microwave MUST
be mounted to BOTH a top cabinet AND a wall, and
connected to at least one wall stud. Can NOT be
installed in island or peninsula cabinet arrangements.
•
Cabinet bottom MUST be level to insure proper
installation.
•
Cabinet MUST be capable of supporting a total load
of 110 lbs.
•
Filler blocks recommended for installation when cabinet
front hangs below recessed bottom shelf.