![background image](http://html.mh-extra.com/html/electrolux/icon-professional-e30df74gps/icon-professional-e30df74gps_design-manual_20733035.webp)
35
electroluxicon.com
7
1
/
4
"
3
/
8
"
10"
7
1
/
2
"
12"
22"
1
1
/
8
"
max.
Approximate location
of junction box
25" min.
36" min.
13"
max.
cabinet
depth
1" min. recommended
distance between rear
edge of cutout and
nearest combustible
surface above countertop
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
7
1
/
2
" min. to nearest
combustible wall
(either side of unit)
*35
3
/
16
"
* 35
15
/
16
"
24"
35
3
/
16
"
*Both cutout dimensions are critical to proper cooktop
installation. Due to variations in countertop materials
it is recommended to undercut finished dimension
(35-15/16") and adjust upon installation of cooktop.
4" x 8" opening to
route armored cable
Side inset
3
/
8
"
Optional 9" stainless
steel backsplash
7
3
/
4
"
25
3
/
4
"
35
7
/
8
"
2"
Optional
Accessories
Depth Adjustment
Filler Kit
PN # 903051-9010
9" Stainless
Steel Backsplash
PN # 903048-9010
Black Knobs Kit
PN # 903127-9010
Installation Specifications
•
Product Weight – 68 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
•
Connected Load (kW Rating) @ 240 / 208 Volts =
11.8 / 8.8 kW
•
Amps @ 240 / 208 Volts = 49.2 / 42.6 Amps
•
Always consult local and national electric codes.
•
Respect critical dimensions as noted for proper
installation of cooktop.
•
Allow 2" space below armored cable opening to clear
electrical cable and allow space for installation of junction
box on wall at back of cooktop.
•
Overhead cabinetry should not exceed a 13"
maximum depth.
•
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
•
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be
no less than maximum width of appliance.
•
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
•
Allow 1" minimum clearance between rear edge of cutout
and nearest combustible surface above countertop.
•
Allow 7-1/2" minimum clearance from edge of cooktop
to nearest combustible wall on either side of unit.
•
Drawers not recommended beneath cooktop.
•
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 7" beyond bottom of cabinets.
Combination Installations
For installation details refer to Project Planning Section.
•
Cooktop model E36EC75HSS is NOT approved to be
used over any Electrolux ICON
®
Single Wall Oven.
•
Cooktop model E36EC75HSS
(without optional
backsplash)
is approved to be used in combination with
an Electrolux ICON
®
36" Downdraft Vent.
(Refer to
Slide-In Cooktop / Downdraft Vent Countertop Preparation
page for installation specifications.)
planning
information
For 36"
electric model:
E36EC75HSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Gas and Electric Slide-In Cooktops