background image

27

Foreword

The installation,

 

use and maintenance Manual

 

(hereinafter Manual) provides the user with information 

necessary for correct and safe use of the machine (hereinafter “machine”, “refrigerator” or “appliance”).

The following must not be considered a long and exacting list of warnings, but rather a set of instructions 

suitable for improving machine performance in every respect and, above all, preventing injury to persons 

and animals and damage to property due to improper operating procedures.

All persons involved in machine transport, installation, commissioning, use and maintenance, repair and disassembly 

must consult and carefully read this manual before carrying out the various operations, in order to avoid wrong and 

improper actions that could compromise the machine’s integrity or endanger persons. Make sure to periodically inform 

the appliance user regarding the safety regulations. It is also important to instruct and update personnel authorised to 

operate on the machine, regarding its use and maintenance.

The manual must be available to operators and carefully kept in the place where the machine is used, so that it is 

always at hand for consultation in case of doubts or whenever required.

If, after reading this manual, there are still doubts regarding machine use, do not hesitate to contact the Manufacturer or 

the authorised after-sales service centre, to receive prompt and precise assistance for better operation and maximum 

efficiency of the machine.

During all stages of machine use, always respect the current regulations on safety, work hygiene and environmental 

protection. It is the user’s responsibility to make sure the machine is started and operated only in optimum conditions 

of safety for persons, animals and property.

The manufacturer declines any liability for operations carried out on the appliance without respecting the 

instructions given in this manual.

No part of this manual may be reproduced.

EN

Содержание GP379

Страница 1: ...ng the safety regulations It is also important to instruct and update personnel authorised to operate on the machine regarding its use and maintenance The manual must be available to operators and carefully kept in the place where the machine is used so that it is always at hand for consultation in case of doubts or whenever required If after reading this manual there are still doubts regarding ma...

Страница 2: ...more hazards Risk a combination of probabilities and risks of injury or harm to health in a hazardous situation Protection devices safety measures consisting of the use of specific technical means guards and safety devices for protecting operators against dangers Guard an element of a machine used in a specific way to provide protection by means of a physical barrier Safety device a device other t...

Страница 3: ...of use concerning safety hygiene and health in the workplace The Manufacturer declines any liability for damage caused by arbitrary modifications and conversions carried out by the user or the Customer The employer workplace manager or service technician are responsible for identifying and choosing adequate and suitable personal protection equipment to be worn by operators in compliance with regul...

Страница 4: ... 543 Rack dimensions mm 325X530 325X530 325X530 2 compartments Weight kg 87 Temp range in compartment C 2 10 Max room temp era ture C 43 3 compartments Weight kg 126 Temp range in compartment C 2 10 Max room temp era ture C 43 4 compartments Weight kg 151 Temp range in compartment C 2 10 Max room temp era ture C 43 Recommended condensing unit for counter 2 3 compartments model CML60TB3N Power supp...

Страница 5: ...mustbestoredandprotectedagainst damp in a non aggressive place free of vibrations and with room temperature between 10 C and 50 C The place where the machine is stored must have a flat support surface in order to avoid any twisting of the machine or damage to the support feet ATTENTION Machine positioning installation and disassembly must be carried out by a specialised technician ATTENTION Do not...

Страница 6: ... depart ment for details or use a more powerful refrigeration unit Install on the delivery line in the following order a suitably sized dehydration filter a liquid flow indicator and a solenoid valve if not present B 2 6 EVACUATING THE LINES AND CHARGING WITH REFRIGERANT GAS for installation with remote refrigeration unit ATTENTION CHARGING WITH REFRIGERANT MUST BE DONE BY PROFESSIONALLY QUALIFIED...

Страница 7: ...a position always visible to the operator perform ing the intervention during maintenance operations After making the connection with the appliance running check that the power supply does not fluctuate by 10 the rated voltage ATTENTION An H05VV F power cable designation 60227 IEC 53 is used for the permanent connection to the power supply when replacing it use a type having at least these charact...

Страница 8: ...is run into a tray and automatically evaporated Manual defrost activation Keep the DOWN button pressed for at least 5 seconds to start a manual defrost cycle This function is signalled by lighting up of the DEFROST icon If defrost conditions do not exist the display shows the message dFb indicating that the operation will not be carried out only for models 15 C 22 C and 2 C 10 C Defrost can be sto...

Страница 9: ...structural changes or modifications to the operating logic tampering with the guards or safety devices failure to use personal protection equipment by operators specialised technicians and maintenance personnel failure to use suitable accessories e g use of unsuitable equipment or ladders keeping combustible or flammable materials or in any case materials not compatible with or pertinent to the wo...

Страница 10: ...l carefully following the instructions given below The manufacturer declines any liability for operations carried out on the machine without following these instructions D 1 1 2 Cleaning the cabinet and accessories Be fo re us ing the appli ance cl e an all the in si de pa rts an d ac ces sor ies wi th lukewa rm wa ter an d ne ut ral so ap or pr odu cts th at are over 90 bio degra dable in order t...

Страница 11: ...ce PNC production number code the Ser No appliance serial number Note The code and serial number are essential for identifying the type of appliance and date of manufacture appliance identification code fourth digit of the year of production 2015 third digit of the year of production 2015 week 50 10th piece produced in the week Ser No 5 50 1 0010 PNC 728304 23 D 1 3 MAINTENANCE INTERVALS The inspe...

Страница 12: ...ECTED D 2 1 WASTE STORAGE At the end of the product s life cycle make sure it is not dispersed in the environment The doors must be removed before scrapping the appliance Special waste materials can be stored temporarily while awaiting treatment for disposal and or permanent storage In any case the current environmental protection laws in the country of use must be observed D 2 2 PROCEDURE REGARDI...

Отзывы: