background image

36

 C.4 NORMAL MACHINE USE

C.4.1 CHARACTERISTICS OF PERSONNEL TRAINED FOR  

 

NORMAL MACHINE USE

The Customer must make sure the personnel for normal machine 

use are adequately trained and skilled in their duties, as well as 

ensuring their own safety and that of other persons.

The Customer must make sure his personnel have understood 

the instructions received and in particular those regarding work 

hygiene and safety in use of the machine.

C.4.2 CHARACTERISTICS OF PERSONNEL ENABLED TO  

 

OPERATE ON THE MACHINE

The Customer is responsible for ensuring that persons assigned 

to the various duties:

•  read and understand the manual;

•  receive adequate training and instruction for their duties in 

order to perform them safely;

•  receive specific training for correct machine use.

C.4.3 OPERATOR FOR NORMAL MACHINE USE

He must have at least:

•  knowledge  of  the  technology  and  specific  experience  in 

operating the machine;

•  adequate general basic education and technical knowledge 

for reading and understanding the contents of the manual;

•  including correct interpretation of the drawings, signs and 

pictograms;

•  sufficient technical knowledge for safely performing his duties 

as specified in the manual;

•  knowledge of the regulations on work hygiene and safety.

In case of a significant fault (e.g. short circuits, wires coming out 

of the terminal block, motor breakdowns, worn electrical cable 

sheathing, etc.) the operator for normal machine use must:

•  immediately deactivate the machine.

D.1  MACHINE CLEANING AND  

 

  MAINTENANCE

 ATTENTION!

 

Before carrying out any cleaning or maintenance 

operation, disconnect the appliance from the 

power supply and carefully unplug it.

 

Disconnect the appliance from the power supply at 

least 30 minutes before carrying out any cleaning 

or maintenance operation. 

 ATTENTION!

 

During maintenance, the cable and plug must be 

kept in a visible position by the operator carrying 

out the work.

 ATTENTION!

 

Do not touch the appliance with wet hands or 

feet or when barefoot. Do not remove the safety 

guards.

 ATTENTION!

 

Use suitable personal protection equipment (pro-

tective gloves).

D.1.1 ROUTINE MAINTENANCE 

 ATTENTION!

 

Disconnect the power supply before cleaning the 

appliance.

D.1.1.1 Precautions for maintenance 

Routine maintenance operations can be carried out by non-

specialised personnel, carefully following the instructions 

given below. 

The manufacturer declines any liability for 

operations carried out on the machine without following 

these instructions.

D.1.1.2 Cleaning the cabinet and accessories

Be fo re  us ing  the  appli ance,  cl e an  all  the  in si de  pa rts  an d  ac ces-

sor ies  wi th  lukewa rm  wa ter  an d  ne ut ral  so ap  or  pr odu cts  th at 

are over 90% bio degra dable (in order to reduce the emission of 

pollutants into the envi ronment), then rinse and dry thoroughly. 

Do  not  use  so lvent-based  deter gents  (e.g.  tri chl oro-ethylene)        or 

abrasive powders for cleaning.

It is advisable to go over the stainless steel surfaces with a rag 

moistened with paraffin oil in order to create a protective film. 

Check the power cable regularly and replace it in case of signs 

of wear.

Have the appliance checked periodically (at least once a year).

 ATTENTION!

 

Do not clean the machine with jets of water.

 ATTENTION!

 

Do not use steel wool or similar material to clean 

stainless steel surfaces. Do not use detergents 

containing chlorine, solvent-based detergents 

(e.g. trichloro-ethylene) or abrasive powders.

D.1.1.3 Compartment cleaning

To clean the com partment, remove all the racks, remove the 

screws  fixing  the wire  structures, clean  the compartment  with 

products that are over 90% bio deg rable, th en rin se and dry tho-

ro ug hly  .

ATTENTION:

 These appliances do not have a water drain hole. 

For refrigerated models: periodically clean the defrost water 

drain hole (located on the back of the compartment) by 

means of the “swab” provided, it order to clear the hole if 

clogged (see figure below)

ATTENTION!

 

After cleaning, do not leave the “swab” in the 

drain hole.

NOTE: This operation cannot be carried out on freezer 

models.

D.1.1.4 Precautions in case of long idle periods

If   the   ap pli an ce  is   not  go ing  to   be   us ed  for  so me  ti me,  ta ke  the 

fo ll ow ing  precautions:

•  unplug   it      ;

•  remove all food from the compartment and clean the inside 

and accessories;

•  le ave    the  do or  aj ar  so  th at  a ir  can  ci rc ul ate  in si de,  pr even ti ng 

th e  fo rm at ion  of  un pl ea sant  odours;

•  a ir  th e  premises   p e ri od ic al ly.

 ATTENTION!

 

Machine maintenance, checking and overhaul op-

erations must only be carried out by a specialised 

Technician or the After-Sales Service, provided 

with adequate personal protection equipment 

(safety shoes and gloves), tools and ancillary 

means.

 ATTENTION!

 

Work on the electrical equipment must only be 

carried out by a specialised electrician or the 

After-Sales Service.

Содержание GP379

Страница 1: ...ng the safety regulations It is also important to instruct and update personnel authorised to operate on the machine regarding its use and maintenance The manual must be available to operators and carefully kept in the place where the machine is used so that it is always at hand for consultation in case of doubts or whenever required If after reading this manual there are still doubts regarding ma...

Страница 2: ...more hazards Risk a combination of probabilities and risks of injury or harm to health in a hazardous situation Protection devices safety measures consisting of the use of specific technical means guards and safety devices for protecting operators against dangers Guard an element of a machine used in a specific way to provide protection by means of a physical barrier Safety device a device other t...

Страница 3: ...of use concerning safety hygiene and health in the workplace The Manufacturer declines any liability for damage caused by arbitrary modifications and conversions carried out by the user or the Customer The employer workplace manager or service technician are responsible for identifying and choosing adequate and suitable personal protection equipment to be worn by operators in compliance with regul...

Страница 4: ... 543 Rack dimensions mm 325X530 325X530 325X530 2 compartments Weight kg 87 Temp range in compartment C 2 10 Max room temp era ture C 43 3 compartments Weight kg 126 Temp range in compartment C 2 10 Max room temp era ture C 43 4 compartments Weight kg 151 Temp range in compartment C 2 10 Max room temp era ture C 43 Recommended condensing unit for counter 2 3 compartments model CML60TB3N Power supp...

Страница 5: ...mustbestoredandprotectedagainst damp in a non aggressive place free of vibrations and with room temperature between 10 C and 50 C The place where the machine is stored must have a flat support surface in order to avoid any twisting of the machine or damage to the support feet ATTENTION Machine positioning installation and disassembly must be carried out by a specialised technician ATTENTION Do not...

Страница 6: ... depart ment for details or use a more powerful refrigeration unit Install on the delivery line in the following order a suitably sized dehydration filter a liquid flow indicator and a solenoid valve if not present B 2 6 EVACUATING THE LINES AND CHARGING WITH REFRIGERANT GAS for installation with remote refrigeration unit ATTENTION CHARGING WITH REFRIGERANT MUST BE DONE BY PROFESSIONALLY QUALIFIED...

Страница 7: ...a position always visible to the operator perform ing the intervention during maintenance operations After making the connection with the appliance running check that the power supply does not fluctuate by 10 the rated voltage ATTENTION An H05VV F power cable designation 60227 IEC 53 is used for the permanent connection to the power supply when replacing it use a type having at least these charact...

Страница 8: ...is run into a tray and automatically evaporated Manual defrost activation Keep the DOWN button pressed for at least 5 seconds to start a manual defrost cycle This function is signalled by lighting up of the DEFROST icon If defrost conditions do not exist the display shows the message dFb indicating that the operation will not be carried out only for models 15 C 22 C and 2 C 10 C Defrost can be sto...

Страница 9: ...structural changes or modifications to the operating logic tampering with the guards or safety devices failure to use personal protection equipment by operators specialised technicians and maintenance personnel failure to use suitable accessories e g use of unsuitable equipment or ladders keeping combustible or flammable materials or in any case materials not compatible with or pertinent to the wo...

Страница 10: ...l carefully following the instructions given below The manufacturer declines any liability for operations carried out on the machine without following these instructions D 1 1 2 Cleaning the cabinet and accessories Be fo re us ing the appli ance cl e an all the in si de pa rts an d ac ces sor ies wi th lukewa rm wa ter an d ne ut ral so ap or pr odu cts th at are over 90 bio degra dable in order t...

Страница 11: ...ce PNC production number code the Ser No appliance serial number Note The code and serial number are essential for identifying the type of appliance and date of manufacture appliance identification code fourth digit of the year of production 2015 third digit of the year of production 2015 week 50 10th piece produced in the week Ser No 5 50 1 0010 PNC 728304 23 D 1 3 MAINTENANCE INTERVALS The inspe...

Страница 12: ...ECTED D 2 1 WASTE STORAGE At the end of the product s life cycle make sure it is not dispersed in the environment The doors must be removed before scrapping the appliance Special waste materials can be stored temporarily while awaiting treatment for disposal and or permanent storage In any case the current environmental protection laws in the country of use must be observed D 2 2 PROCEDURE REGARDI...

Отзывы: