![Electrolux FPUH17D7KF All Freezer Professional Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/electrolux/fpuh17d7kf-all-freezer-professional-series/fpuh17d7kf-all-freezer-professional-series_servicing_94073012.webp)
2-4
Never unplug the freezer by pulling on the
power cord. Always grip the plug firmly and pull
straight out from the receptacle.
Turning the control to “OFF” turns off the com-
pressor but does not disconnect power to other
electrical components.
WARNING
Avoid fire hazard or electric shock. Do not use
an extension cord or an adapter plug. Do not
remove any prong from the power cord.
WARNING
Electrical Information
These guidelines must be followed to ensure that safety
mechanisms in the design of this freezer will operate
properly.
Refer to the serial plate for correct electrical rating. The
power cord of the unit is equipped with at three-prong
grounding plug for protection against shock hazards. It
must be plugged directly in to its own properly grounded
three-prong receptacle, protected with a 15 amp time
delay fuse or circuit breaker. The receptacle must be
installed in accordance with the current edition of the
National Electrical Code (NFPA 70) the local codes and
ordinances. Consult a qualified electrician. Receptacles
with Ground Fault Circuit Interrupters (GFCI) are NOT
RECOMMENDED. DO NOT USE AN EXTENSION CORD
OR AN ADAPTER PLUG.
If the voltage varies by 10% or more, freezer and/or
refrigerator performance may be affected. Operating the
freezer with insufficient power can damage the motor.
Such damage is not covered under the warranty. If you
suspect your voltage is high or low, consult your power
company for testing.
To prevent the freezer from being turned off accidentally,
do not plug the unit in to an outlet controlled by a wall
switch or pull cord.
Do not pinch, knot, or bend the power cord in any
manner.
Leveling
The freezer and/or refrigerator must have all bottom
corners resting firmly on a solid floor. The floor must be
strong enough to support a fully loaded freezer and/or
refrigerator.
It is VERY IMPORTANT for your freezer and/or
refrigerator to be level in order to function properly. If
the unit is not leveled during installation, the door/lid
may be misaligned and not close or seal properly,
causing cooling, frost or moisture problems.
After discarding crating screws and wood base, use a
carpenter’s level to level the unit from front to back.
Adjust the plastic leveling feet in front, ½ bubble higher,
so that the door closes easily when left half way open.
Figure 2-2. Electrical Receptacle
Section 2 Installation Information
Figure 2-3. Leveling Unit
Содержание FPUH17D7KF All Freezer Professional Series
Страница 2: ......
Страница 20: ...Section 2 Installation Information 2 12 Figure 2 20 Figure 2 21 ...
Страница 21: ...Section 2 Installation Information 2 13 Figure 2 22 Figure 2 23 ...
Страница 24: ...Section 2 Installation Information 2 16 Notes ...
Страница 26: ...Section 3 Electronic Control 3 2 Notes ...
Страница 41: ...Section 4 Refrigeration 4 15 HFC 134a CFC 12 Pressure Temperature Chart ...
Страница 44: ...Section 4 Refrigeration 4 18 Notes ...
Страница 68: ...Section 6 Parts List 6 2 All Refrigerator Cabinet Exploded View And Parts List ...
Страница 70: ...Section 6 Parts List 6 4 All Refrigerator Sealed System Exploded View And Parts List ...
Страница 72: ...Section 6 Parts List 6 6 All Freezer Door Exploded View And Parts List ...
Страница 74: ...Section 6 Parts List 6 8 All Freezer Cabinet Exploded View And Parts List ...
Страница 76: ...Section 6 Parts List 6 10 All Freezer Sealed System Exploded View And Parts List ...
Страница 78: ...Section 6 Parts List 6 12 Notes ...
Страница 82: ...Section 7 Troubleshooting 7 4 Notes ...
Страница 83: ...Section 8 Wiring Diagram 8 1 All Refrigerator Wiring Diagram ...
Страница 84: ...8 2 Section 8 Wiring Diagram All Freezer Wiring Diagram ...