refrigerants safely in accordance
with an industry recognised
assessment specification.
•
Servicing shall only be
performed as recommended by
the equipment manufacturer.
Maintenance and repair
requiring the assistance of other
skilled personnel shall be carried
out under the supervision of the
person competent in the use of
flammable refrigerants.
•
The appliance shall be stored
so as to prevent mechanical
damage from occurring.
•
Keep ventilation openings clear
of obstruction.
NOTE:
The following informations are
required for the units adopt R32/R290
Refrigerant.
•
The appliance shall be stored in a
room without continuously operating
ignition sources (for example: open
flames, an operating gas appliance or
an operating electric heater).
•
Do not pierce or burn.
•
Be aware that the refrigerants may not
contain an odour.
•
Compliance with national gas
regulations shall be observed.
•
Appliance shall be stored in a well-
ventilated area where the room size
corresponds to the room area as
specified for operation.
•
Appliance shall be installed, operated
and stored in a room with a floor area
larger than X m² (Please see the
following form). The appliance shall not
be installed in an unventilated space,
if that space is smaller than X m²
(Please see the following form).
Note about Fluorinated Gasses
1.
This air-conditioning unit contains
fluorinated gasses. For specific
information on the type of gas and
the amount, please refer to the
relevant label on the unit itself.
2.
Installation, service, maintenance
and repair of this unit must be
performed by a certified technician.
3.
Product uninstallation and recycling
must be performed by a certified
technician.
4.
If the system has a leak-detection
system installed, it must be checked
for leaks at least every 12 months.
5.
When the unit is checked for leaks,
proper record-keeping of all checks
is strongly recommended.
Model (Btu/h)
Amount of refrigerant
to be charged (kg)
Maximum installation
height (m)
Minimum room
area (m²)
≤30000
≤2.048
2.2m
4
≤30000
≤2.048
1.8m
4
≤30000
≤2.048
0.6m
35
30000-48000
2.048-3.0
2.2m
4
30000-48000
2.048-3.0
1.8m
8
30000-48000
2.048-3.0
0.6m
80
>48000
>3.0
2.2m
5
>48000
>3.0
1.8m
9
>48000
>3.0
0.6m
80