FUNCTION OF AUTOMATIC WIRING/PIPING
CORRECTION
10.2
Test Run Instructions
1.
Open both the liquid and gas stop
valves.
2.
Turn on the main power switch and
allow the unit to warm up.
3.
Set the air conditioner to COOL
mode.
4.
For the Indoor Unit
a.
Ensure the remote control and
its buttons work properly.
b.
Ensure the louvers move properly
and can be changed using the
remote control.
c.
Double check to see if the room
temperature is being registered
correctly.
d.
Ensure the indicators on the remote
control and the display panel on the
indoor unit work properly.
e.
Ensure the manual buttons on the
indoor unit works properly.
f.
Check to see that the drainage
system is unimpeded and draining
smoothly.
g.
Ensure there is no vibration or
abnormal noise during operation.
5.
For the Outdoor Unit
a.
Check to see if the refrigeration
system is leaking.
b.
Make sure there is no vibration or
abnormal noise during operation.
c.
Ensure the wind, noise, and water
generated by the unit do not disturb
your neighbors or pose a safety
hazard.
NOTE:
If the unit malfunctions or
does not operate according to your
expectations, please refer to the
Troubleshooting section of the Owner’s
Manual before calling customer service.
11.1
Automatic Wiring/Piping
Correction Function
More recent models now feature
automatic correction of wiring/piping
errors. Press the “check switch”
on the outdoor unit PCB board for
5 seconds until the LED displays “CE”,
indicating that this function is working,
Approximately 5-10 minutes after the
switch is pressed, the “CE” disappears,
meaning that the wiring/piping error is
corrected and all wiring/piping is properly
connected.