11
ENGLISH
:
+
Fig. 6.5
$
%
'
Fig. 6.6
Table 6.1:
Length Specifications of Split
Type Outdoor Unit (unit: mm/inch)
Outdoor Unit
Dimensions
W x H x D
Mounting
Dimensions
Distance
A
Distance
B
760x590x285
(29.9x23.2x11.2)
530
(20.85)
290
(11.4)
810x558x310
(31.9x22x12.2)
549
(21.6)
325
(12.8)
845x700x320
(33.27x27.5x12.6)
560
(22)
335
(13.2)
900x860x315
(35.4x33.85x12.4)
590
(23.2)
333
(13.1)
945x810x395
(37.2x31.9x15.55)
640
(25.2)
405
(15.95)
990x965x345
(38.98x38x13.58)
624
(24.58)
366
(14.4)
938x1369x392
(36.93x53.9x
15.43)
634
(24.96)
404
(15.9)
Outdoor Unit
Dimensions
W x H x D
Mounting
Dimensions
Distance
A
Distance
B
900x1170x350
(35.4x46x13.8)
590
(23.2)
378
(14.88)
800x554x333
(31.5x21.8x13.1)
514
(20.24)
340
(13.39)
845x702x363
(33.27x27.6x14.3)
540
(21.26)
350
(13.8)
946x810x420
(37.2x31.9x16.53)
673
(26.5)
403
(15.87)
946x810x410
(37.2x31.9x16.14)
673
(26.5)
403
(15.87)
952x1333x410
(37.5x52.5x16.14)
634
(24.96)
404
(15.9)
952x1333x415
(37.5x52.5x16.14)
634
(24.96)
404
(15.9)
Rows of series installation
Table 6.2
The relations between
H, A and L are as follows.
L
A
L ≤ H
L ≤ 1/2H
25cm / 9.8″
or more
1/2H < L ≤ H 30cm / 11.8″
or more
L > H
Can not be installed
/
+
FP
ರRUPR
UH
$
FP
ರ
RUPR
UH
F
P
ರ
RUPR
UH
FP
ರ
RUPRUH
FP
ರ
RUP
RUH
Fig. 6.7
NOTE:
The minimum distance between
the outdoor unit and walls described in
the installation guide does not apply to
airtight rooms. Be sure to keep the unit
unobstructed in at least two of the three
directions (M, N, P) (See Fig. 6.8)