D)
Natural Gas pipe holder
E)
LPG pipe holder
The appliance is set to default
gas, to change the setting choose
pipe holder from the list. Always
use the gasket sealing
12.4
Adjustment to different
types of gas
WARNING!
Let only an authorized person do
the adjustment to different types
of gas.
This appliance is for operation
with natural gas.
With the correct injectors, you can
also operate it with liquid gas.
WARNING!
Before replacing the injectors,
make sure that the gas knobs are
in the Off position and disconnect
the appliance from the electrical
supply. Let the appliance cool off
fully. There is a risk of injury.
12.5
Injectors replacement
1.
Remove the pan supports.
2.
Remove the caps and crowns of the
burner.
3.
Remove the injectors with a socket
spanner 7. Replace them with the
ones necessary for the type of gas
you use.
To change to Town Gas (G110/
G120/G2.350), attach the air reg-
ulator onto the main jets. Spin it
as tight as you can.
4.
Assemble back the parts. Do the
same procedure but start from its
end.
5.
Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the bag supplied with the
appliance.
If the supply gas pressure is not constant
or it is different from the necessary pres-
sure, install an applicable pressure adjust-
er on the gas supply pipe.
12.6
Adjustment of minimum
level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-
pass screw position (A). The bypass
screw position (A) depends on model.
A
• If you change from natural gas to liquid
gas, fully tighten the adjustment screw
in.
• If you change from liquid gas to natural
gas, undo the by-pass screw approxi-
mately 1/4 of a turn (1/2 of a turn for
the Triple Crown burner).
ENGLISH