Wiring diagram with spindle
position;
stop, left
Fig. Wiring diagram
The temperature can be selected according to the knob position.
After beginning of work, contact 1-2 is closed.
To check the thermostat, measure the temperature in the muffle. Determine the following
temperatures:
-
Hot air 160 °C ± 15 °C
-
Conventional 200 °C ± 15 °C
-
Pyrolysis 485 °C ± 20 °C
If a temperature is found which is beyond the tolerance value, replace the thermostat.