4.2.2 Micro switch for telescopic runner
The appliances with pyrolytic self-cleaning system are provided with a micro switch. The switch
contact is interrupted with the grates suspended. Thus the self-cleaning function cannot be
activated. The contact closes and self-cleaning is possible with the telescopic runners removed.
4.2.3 Temperature and function controllers
Both with the temperature controller and the function controller, each angular degree of switch
turning changes an existing voltage value and/or resistance value. Thus turning the switch results in
a change of the existing temperature at the heater or of the mode of operation. Control is via the
Prisma basic power board.
Fig. Set value transmitter (function and temperature)
Fig. Temperature controller