- 26 -
TSE-N 01.01 A. B.
599 50 86 62EN
7. Fault diagnosis/What to do if ?
7.1 Measuring the temperature sensor
If a failure at the temperature sensor is assumed, the resistance can be checked by means of an
ohmmeter.
The resistance of the temperature sensor should be 500 600 ohms at room temperature.
Make sure to measure the insulation resistance between the metallic housing and each connection
terminal.
The resistance should be higher than 2 MOhms.
Refer to chapter 4.2.5 of Prisma basic power board for failures of consumers and door lock.