![ELECTRO FREEZE SLX400C Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/electro-freeze/slx400c/slx400c_operators-manual_2379681053.webp)
ELECTRO FREEZE Soft Serve Models SLX400C
184582-01
43
14 Trouble Shooting Tables
(continued)
Compressor will
not start – hums
intermittently
(cycling on
overload)
1. Low line voltage.
1.
Ask power company to increase
voltage to not less than 10% below
data plate rating or have transformer
installed. Have electrician check for
adequate wire size.
2. Improperly wired.
2. Contact your Electro Freeze distributor
for service.
3. Open start capacitor or current relay.
3. Contact your Electro Freeze distributor
for service.
4. High discharge pressure.
4. Contact your Electro Freeze distributor
for service.
PROBLEM
PROBABLY CAUSE
REMEDY
Poor or slow
product recovery.
1. Dirty or blocked condenser, restricted air
flow – high ambient temperature.
1.
Have condenser cleaned by your
Electro Freeze distributor; lower
ambient temperature.
2. Defective condenser fan motor.
2. Contact your Electro Freeze distributor
for service.
3. Component or compressor failure.
3. Contact your Electro Freeze distributor
for service.
Beater motor
does not operate.
1. Head assembly is not installed.
1. Install head assembly.
2. Magnetic head switch defective.
2. Contact your Electro Freeze Distributor
for service.
3. Loose connection in control circuit.
3. Contact your Electro Freeze Distributor
for service.
4. Open starter coil.
4. Contact your Electro Freeze Distributor
for service.
5. Faulty capacitor assembly. (Single phase
only.)
5. Contact your Electro Freeze Distributor
for service.
6. Faulty beater motor.
6. Contact your Electro Freeze Distributor
for service.
Содержание SLX400C
Страница 2: ......
Страница 10: ......
Страница 58: ......
Страница 60: ......
Страница 62: ......
Страница 70: ...8 184582 01 ELECTRO FREEZE Soft Serve Models SLX400C Figure 8 Assembly View ...
Страница 73: ...ELECTRO FREEZE Soft Serve Models SLX400C 184582 01 11 O Ring Chart ...
Страница 74: ...12 184582 01 ELECTRO FREEZE Soft Serve Models SLX400C ...