background image

OPERATOR'S MANUAL

with Replacement Parts List

H.C. Duke & Son, LLC   

 

P/N 184584  September, 2016    

    

        Printed in USA

SOFT SERVE 

TWIST MODEL

SLX400C

184582   9/16

Содержание SLX400C

Страница 1: ...OPERATOR S MANUAL with Replacement Parts List H C Duke Son LLC P N 184584 September 2016 Printed in USA SOFT SERVE TWIST MODEL SLX400C 184582 9 16 ...

Страница 2: ......

Страница 3: ...Operator s Manual for the Electro Freeze Model SLX400C Soft Serve Freezers All contents Copyright 2014 H C Duke Son LLC 2116 Eighth Avenue East Moline Illinois 61244 ...

Страница 4: ... messages and the operating instructions in this manual DANGER The signal words DANGER WARNING and CAUTION are used with the safety alert symbol DANGER decals on the freezer may or may not have the safety alert symbol but the message is the same Decals with the words DANGER WARNING or CAUTION appear on the freezer DANGER identifies the most serious hazard Decals with the words DANGER or WARNING ar...

Страница 5: ...pt to repair the freezer until the main power supply has been disconnected Some freezers have more than one disconnect switch Contact your IDQ authorized service representative or H C Duke Son LLC Service Department for original equipment parts 6 Caution This Freezer is to be operated by trained persons The Dispense feature if used by public in self serve applications shall be monitored by trained...

Страница 6: ... and operating instructions in this manual are read and understood Take notice of all warning caution instruction and information decals or labels on the freezer as shown in the figure to the right The labels have been put there to help maintain a safe working environment The labels have been designed to withstand washing and cleaning All labels must remain legible for the life of the freezer Chec...

Страница 7: ...N 165126 3 Hazardousrotatingbeatershaft Donot operateunitwithdispenseheadremoved Beforeremovingdispensehead 1 Setallcontrolsto OFF and 2 setpowerswitchto OFF position WARNING Hazardousrotatingbeatershaft Donot operateunitwithdispanseheadremoved Beforecleaningmachine 1 Setallcontrolsto OFF and 2 setpowerswitchto OFF position WARNING BOTH SIDES ...

Страница 8: ...1 Particulars 5 3 2 Data Plate 6 3 3 Reference Information 6 3 4 Installation Date 7 3 5 Dimensions 7 4 Virtual Quality Management Terminology 8 4 Virtual Quality Management System 9 5 Part Names and Functions 10 6 Operator Controls and Indicators 13 6 14 Mix Feed Tube 16 7 Operator Display Menus 17 8 Disassembly and Cleaning 20 8 1 Cleaning Accessories 20 8 2 Disassembly Instructions 21 8 3 Clean...

Страница 9: ...14 Trouble Shooting Tables 39 14 1 Virtual Quality Management VQM System Display Trouble Shooting Messages 45 Replacement Parts Figure 1 Head Assembly 1 Figure 2 SLX400E Beater Shaft Assembly 2 Figure 3 SLX500 Beater Shaft Assembly 3 Figure 4 Mix Feed Tube Assembly 4 Figure 5 Contactor Box 5 Figure 6 Capacitor Box 5 Figure 7 Control Center 6 Figure 8 Switch Assembly 7 Figure 9 Panel View Sheet 1 o...

Страница 10: ......

Страница 11: ...el SLX400C Make sure all personnel responsible for equipment operation completely read and understand this manual before operating the freezer When properly operated and maintained the freezer will produce a consistent quality product If you require technical assistance please contact your local authorized Electro Freeze Distributor as follows Name Address Phone For factory service assistance cont...

Страница 12: ... in transit If the SHOCKWATCH label indicates red and or the carton is broken torn or punctured note the damage on the carrier s freight bill and notify the carrier s local agent immediately 1 Remove the carton from the pallet and move the machine as close as possible to the permanent location 2 Remove the shipping bolts on the bottom of the freezer figure 2 1 and install either the legs or caster...

Страница 13: ...and Water Waste A manual shut off valve should be installed in the water inlet line at the time of installation The water pressure must be between 35 140 psig 241 965 kPa for proper operation 5 Place the freezer in its final location and adjust the legs or casters so that it is level side to side and the front is approximately 1 4 inch lower than the rear to allow proper drainage of the freezing c...

Страница 14: ...ctrical Connections 5 For all 3 phase freezers beater shaft rotation must be clockwise as viewed from the front of the freezer 4 An easily accessible main power disconnect must be provided for all poles of the wiring to the freezer 2 4Electrical Requirements Model SLX400C ONLY CAUTION To prevent accidental electrical shock a receptacle with a positive earth ground is required 1 Always verify elect...

Страница 15: ... in cm 30 22 76 75 SLX400E Weight lb kg 425 190 Cylinder Compressor 1 HP 6900 BTU hr 1 3 kw Motor 2 1 kw Cooling Beater Motor 2 1 HP 0 75 kw Refrigerant Cylinder R 404a Charge Cylinder lbs kg A C 4 1 81 Charge Cylinder lbs kg W C 3 75 1 7 Cooling Air or Water Hopper qt ltr 2 12 11 4 Cylinder qt ltr 2 2 7 2 6 A C Air Cooled W C Water Cooled ...

Страница 16: ...elow correspond to the call out numbers in figure 3 1 1 Model Number _________________ 2 Serial Number __________________ 3 Electrical Spec Voltage ________ Phase _______ Hertz _________ 4 Max Fuse Size __________________ 5 Min Circuit Ampacity ___________ 3 2Data Plate The data plate provides important information that the operator should record and have available for parts ordering warranty inqu...

Страница 17: ...below This information will be needed when ordering parts or service for the freezer Date of installation ____________________________________ Installed by ____________________________________ Address ____________________________________ ____________________________________ Phone ____________________________________ AIR FLOW AIR FLOW 19 50 49 53 22 12 56 18 23 82 60 51 14 10 35 82 16 48 41 86 5 62...

Страница 18: ...ure and no product is being dispensed Lock outs Allows the function of a specific feature button to be temporarily disabled to deter unnecessary usage of that feature Main P C Board Main Control board for the unit housed behind the trim strip panel This board has many connectors on it and is responsible for the main operations of the unit Membrane Switch The black Electro Freeze decal visible on t...

Страница 19: ... to the operator Adjustable from 1 9 and 5 being neutral no change Lower than 5 colder and greater than 5 warmer U I User Interface The board that lies directly behind the membrane switch on the front panel This board houses the LED screen that displays the menus and operations The membrane switch is connected to this board via a ribbon cable This board also has its own software ...

Страница 20: ...ATED Forms the frozen product as it is dispensed 1 HEAD DISPENSE Encloses the freezing cylinder and provides an opening for product to be dispensed 2 O RINGS HEAD Seals the head to the freezing cylinder Must be lubricated 3 PLUNGERS DISPENSE SIDE Seals the product opening in the head when closed Allows product to flow when open 4 O RINGS PLUNGER Seals the plunger in the head Must be lubricated to ...

Страница 21: ...n the figure 4 SEAL BEATER SHAFT Seals the opening between the freezing cylinder and the beater shaft Consists of the following 5 SEAL BEATER SHAFT 6 WASHER DOUBLE SHAFT SEAL 1 BAR BREAKER Keeps product blended in the center of the beater shaft 2 SHAFT ASSY BEATER Rotates in the freezing cylinder blending air and mix Ejects product when dispensing plunger is opened 3 BLADE SCRAPER Scrapes the froz...

Страница 22: ... number in the figure 1 TUBE MIX FEED Meters the correct amount of mix and air into the freezing cylinder from the hopper 2 SLEEVE REAR MIX FEED Provides adjustment on mix feed rate and a positive shut off of mix flow to the freezing cylinder 3 INSERT MIX FEED TUBE Used to create the proper air mix ratio in the mix feed tube 4 O RING TUBE Seals the opening between the hopper and mix feed tube O ri...

Страница 23: ...operator controls Refer to Fig 6 1 for numbered items in description Note the left side controls operates the left side cylinder and hopper Operation for right side controls is the same The display window has three levels of display Operators Menu Technician Menu and Factory Menu The last two menus are restricted and reserved for use by qualified personnel CAUTION Test operation of the head switch...

Страница 24: ...ged c Night This is the indicator when Night button is pressed In this mode an energy saving feature will activate and reduce product refrigeration The freezer will automatically cycle to maintain temperatures in the cylinder and hopper below 41 F and keep product from deteriorating Use this position when the freezer will not be in use for periods of more than one hour 6 4 OFF Indicator 4 When thi...

Страница 25: ...Off Button 10 Press OFF button to return to main screen display and turn left side of the freezer off 6 11 Left Side Beater ON Button 11 Pressing this button to turn left side beater ON 6 12 Left Side Beater OFF Button 12 Press this button to turn left side beater OFF 6 13 Arrow Buttons 13 Used by technicians for programming an setting changes See Troubleshooting section for Operator accessible co...

Страница 26: ...and place your index finger in the dimple between the 2 3 Gently squeeze the outer sleeve and rotate it till the arrow on the Mix Feed tube is pointed to position 2 on the outer sleeve 2 The plastic mix feed regulator may be adjusted between positions 1 2 3 to obtain an optimum product overrun and dispense speed 3 The 3 setting will allow the least overrun The 1 indent setting will allow the most ...

Страница 27: ... Offset will be shown for left and right barrel Use the Arrow Buttons to move the cursor to highlight the value to be changed once highlighted press the select button and the cursor will now be blinking While the cursor is blinking the value may now be changed using the left or right Arrow Buttons once you have reached the desired setting press select SEL one more time the cursor will now stop bli...

Страница 28: ...ps Hopper Temperature F Left Hopper Right Hopper Barrel Temperature F Left Barrel Right Barrel Event Log Allows the operator to look at logged events i e power switch cycle low mix etc The log will display the last 50 events with the newest event at the top Operator s Menu Options Basic Settings Actual Temps Event Log Error Log Lockouts Information Shown Screen Settings Date Time Last Clean Softwa...

Страница 29: ...ing functions Alternate Moon Y or N Beep Function Y or N unit will or will not beep when a button is pressed Display Hopper Temperature Y or N Will or will not display hopper temp on home screen Hide Clock Error Y or N Date Time Allows user to set the Real Time Clock and current date in the unit Last Clean Displays the last time the unit has been cleaned Software Versions Has current software vers...

Страница 30: ... are necessary for cleaning sanitizing and disassembly assembly 1 HC150009 BRUSH HC158012 HANDLE 4 inch diameter with 36 inch handle used for cleaning the cylinder 2 HC158077 BRUSH 9 16 inch with 36 inch handle used for cleaning the drain tube 3 HC158003 BRUSH Double end 1 1 8 inch diameter and 7 16 inch diameter used for cleaning the mix inlet tube mix feed tube head and general cleaning 4 HC1693...

Страница 31: ...semble and sanitize at the end of every day of operation Figure 8 2 continued 1 If there is product in the freezer refer to Section 11 Closing Procedures 11 2 Draining Product 2 Remove plunger rods 6 figure 8 2 by lifting up and swinging the bottom out and down 3 Remove the hand knobs 8 and gently pull the dispensing head 1 straight out 4 Remove the beater shaft 1 figure 8 3 from each cylinder The...

Страница 32: ... 5 3 and nozzles 11 Remove head o rings 2 and the o rings from plungers 4 5 Remove hopper cover drip tray and insert 6 Remove the mix feed tube figure 8 4 from the hopper CAUTION To prevent bacteria growth remove all O rings when cleaning Failure to do so could create a health hazard 7 Remove the O rings 3 from the mix feed tube 1 Remove the regulator 2 from the mix feed tube Figure 8 4 ...

Страница 33: ...zing the freezer 1 Prepare a three compartment sink for washing rinsing and sanitizing parts removed from the freezer per applicable health codes Also prepare a clean surface to air dry all parts Important Do not use unapproved sanitizer or laundry bleach These materials may contain high concentrations of chlorine bleach and will chemically attack freezer components NOTE The sanitizer should be mi...

Страница 34: ...ts on a clean surface and allow to air dry 5 Using a warm mild dish detergent thoroughly brush a the hoppers and the mix feed tube ports from the hopper to the cylinders figure 8 9 b the inside of the cylinders making certain to clean the back walls with 4 diameter brush provided c the inside of the drain tube figure 8 10 Dip the brush in the dish detergent solution and force brush into the drain ...

Страница 35: ...he shaft seal install the cup seals on the plastic washer as shown in figure 9 1 3 Apply a moderate amount of approved sanitary lubricant such as Petrol Gel to the beater shaft as shown in figure 9 2 Install the shaft seal over the rear of the beater shaft figure 9 2 Do not allow any lubricant to come in contact with the bell shaped rubber portions of the shaft seal 4 Apply lubricant to the bearin...

Страница 36: ...assembly by placing the 2 shorter handles 9 on the sides and the longest handle 10 in the center Lock in place with the handle pin 7 Important Excessive force will damage the head Do not use tools to tighten 11 Install the dispensing head onto the freezer by aligning the studs with the holes in the head and sliding toward the freezer Tighten hand knobs evenly finger tight only 12 Install the plung...

Страница 37: ...bly 13 Install the o rings 3 on the mix feed tube 1 as shown in figure 9 5 Lightly lubricate the o rings Insert the regulator 2 into the mix feed tube Lift slightly and turn to lock the regulator in the CLOSED position figure 9 6 14 Re install drip tray and insert on the freezer Figure 9 6 Closed Position ...

Страница 38: ...lons 7 6 liters of sanitizing solution for each hopper The sanitizing solution must be mixed according to manufacturer s instructions to yield 100 PPM parts per million available chlorine solution example Stera Sheen Green Label Use warm water 100 110 F or 38 43 C to wash rinse and sanitize Make sure sanitizer is mixed thoroughly and has completely dissolved Figure 10 2 Sanitize hopper and its com...

Страница 39: ...ss the soft key under the icon and BEATER ON for both sides of the freezer and allow the beaters to run for 5 minutes During this time period check for leaks around the head plungers and drain tubes 8 Press BEATER OFF on both sides Place an empty container under the dispensing head and drain the sanitizing solution by opening the plungers to allow cylinders and hoppers to empty Open and close each...

Страница 40: ... 10 2 2 depending on freezer setup 1 Place a bucket under the dispense head 2 While filling the mix hopper with one gallon of mix open the plunger by pulling the dispense handle down and allow mix to push out remaining sanitizer When pure mix is flowing from the dispense head close the dispense handle figure 10 4 Important Failure to completely remove sanitizer or water from the freezing cylinder ...

Страница 41: ...nse head close the dispense handle figure 10 4 Reinstall the actuator rod Important Failure to completely remove sanitizer or water from the freezing cylinder before placing in freeze will damage the freezer 3 Press the freeze button to start the freezer 4 Repeat Steps 1 3 for the other side of the freezer 5 Sanitize and install nozzles 10 2 2 Priming Instructions for Freezers Built into a Wall Fi...

Страница 42: ...urfaces with soap and water Use sanitizing solution in a spray bottle and brush to clean the bottom of the plunger openings 4 Turn the mix feed regulator to the CLOSED position 5 Check mix level in hopper to ensure that there is enough mix to keep the indicator light off add mix if necessary Do not dispense product when the mix feed regulator is in the CLOSED position 6 To start the machine after ...

Страница 43: ...ter to run for 5 minutes 13 Place an empty container under the dispensing head and drain the solution by opening the plunger to allow cylinder and hopper to empty 14 When the sanitizing solution has drained from the freezer press BEATER OFF Place the power switch to the OFF position 15 Proceed to disassembly cleaning and sanitizing instructions Figure 11 2 Sanitize hopper Note It is your responsib...

Страница 44: ...entage Weight of liquid mix minus weight of frozen product divided by the frozen weight Multiply by 100 See example Example Weight of 1 pint of mix 18 oz Weight of 1 pint frozen product 12 oz Difference 6 oz 6 oz divided by 12 oz 5 5 x 100 50 overrun Your Electro Freeze Distributor can provide a scale P N HC158049 that is graduated in overrun percentage 12 2 Rerun 4 Once a week run the mix as low ...

Страница 45: ... any O ring that is worn torn or loose fitting 4 Wipe all exterior surfaces of the freezer to remove any splattered mix 5 Check overrun and temperature of the product Electro Freeze recommends the following schedule to help maintain your freezer in like new operating condition Take the time to learn and perform these routine procedures and receive in return many years of valuable service from your...

Страница 46: ...the power switch OFF DO NOT place the freezer in service until the problem has been corrected The head switch feature is designed to prevent the beater shaft from being accidentally activated The beater motors should not operate with the head assembly removed It is essential that the proper operation of this switch be verified routinely Use the following instructions to test for proper operation C...

Страница 47: ...our Electro Freeze Distributor to check water cooled condenser and flush clean to remove scale and deposits if necessary SEMIANNUALLY 1 Contact your Electro Freeze distributor to replace drive belts 2 On air cooled and air cooled remote freezers have your Electro Freeze distributor check the condenser fan motor oil Quarterly 1 Have your Electro Freeze Distributor check the refrigeration system and...

Страница 48: ...nser fins cleaned by an authorized service technician 7 On water cooled freezers disconnect the water supply Use compressed air to blow out all remaining water in the condenser Important The water valve must be opened in order to blow out the condenser Failure to purge the freezer of water can result in severe damage to the refrigeration system Call your Electro Freeze Distributor for service 8 Wh...

Страница 49: ...isconnected Some freezers have more than one disconnect switch Important Some refrigerants are hazardous to the Earth s atmosphere To protect our environment use a refrigerant recovery recycling unit when removing refrigerant from the system THIS SAFETY ALERT SYMBOL IDENTIFIES IMPORTANT PERSONAL SAFETY MESSAGES IN THIS MANUAL WHEN YOU SEE THIS SYMBOL BE ALERT TO THE POSSIBILITY OF PERSONAL INJURY ...

Страница 50: ...ut out control 4 Contact your Electro Freeze distributor for service 5 Disconnected or broken wire in electrical circuit 5 Contact your Electro Freeze distributor for service PROBLEM PROBABLY CAUSE REMEDY Leakage of mix or water from drain tube to drip tray 1 Damaged beater shaft seal or installed improperly 1 Replace cup seals on washer Install properly 2 Beater shaft pitted or damaged where o ri...

Страница 51: ...es slowly out of dispensing head 1 Product too cold 1 Check product temperature Should be 17 to 19 F 8 to 7 C See Trouble shooting Table Dispensed product too hard 2 Dispensing speed adjustment bolt too far down 2 Contact your Electro Freeze distributor for service 3 Wrong rotation on beater 3 Have an electrician correct rotation to clockwise as viewed from the front of the freezer Dispensed produ...

Страница 52: ...essor does not operate or operates improperly 1 Trouble in compressor condensing circuit 1 See Troubleshooting Chart Compres sor Condensing Circuit Section 16 1 2 Faulty start capacitor run capacitor or relay Single phase only 2 Contact your Electro Freeze Distributor for service 3 Faulty contactor 3 Contact your Electro Freeze Distributor for service 4 Disconnected or broken wire in switch or cap...

Страница 53: ...Dirty or blocked condenser restricted air flow high ambient temperature 1 Have condenser cleaned by your Electro Freeze distributor lower ambient temperature 2 Defective condenser fan motor 2 Contact your Electro Freeze distributor for service 3 Component or compressor failure 3 Contact your Electro Freeze distributor for service Beater motor does not operate 1 Head assembly is not installed 1 Ins...

Страница 54: ...er or contact your Electro Freeze Distributor for service 3 Restricted water cooled condenser water cooled models 3 Contact your Electro Freeze Distributor for service 4 Dirty air condenser air cooled models 4 Contact your Electro Freeze Distributor for service 5 Unit location too warm air cooled models 5 Contact your Electro Freeze Distributor for service 6 Refrigerant overcharge 6 Contact your E...

Страница 55: ...ter 2 Failed Condenser fan motor Air Cooled Only 3 Water Supply Shut off Water Cooled Only 1 Remove and clean Condenser pre filter Contact your Electro Freeze Distributor for Service Barrel Rfg Barrel Refrigeration in Night Mode Hopper refrigeration stays on Barrel Refrigeration Error This occurs when the system run time exceeds 90 minutes Cycle the Main Power Switch 1 Dirty Condenser 2 Shortage o...

Страница 56: ...ch defective 3 Loose Wire Connection 4 Programming issue 1 Install Head Assembly 2 Contact your Electro Freeze Distributor for Service Motor OVLD Affected barrel in off mode hopper still operates Motor Overload Open Occurs when motor current is 0 when motor is given an on signal Cycle the Main Power Switch 1 Product too cold 2 Loose wire Connection 3 Open starter coil 4 Faulty Capacitor 1 ph Only ...

Страница 57: ...istorted in any way 3 Install the correct push rod or call your Electro Freeze Distributor to order the correct push rod 4 Contact your Electro Freeze Distributor for Service 5 Contact your Electro Freeze Distributor for Service C Spigot Affected side compressor and beater motor are off until condition is reset Displays Spigot if the Left or Right Side Spigot switch is engaged for more than 5 min ...

Страница 58: ......

Страница 59: ...nted in U S A Quality Parts PROTECT YOUR EQUIPMENT Keep Your Freezer In Excellent Condition Always Contact Your Electro Freeze Distributor For Replacement Parts SOFT SERVE TWIST MODEL SLX400C 184582 01 7 14 REPLACEMENT PARTS MANUAL with ILLUSTRATIONS ...

Страница 60: ......

Страница 61: ..._______ Address _______________________ ______________________________ Phone ________________________ If you require any further assistance contact H C Duke Son LLC Electro Freeze as follows Phone 309 755 4553 800 755 4545 FAX 309 755 9858 E mail service electrofreeze com Replacement Parts Orders ELECTRO FREEZE Soft Serve Model SLX400C Table of Contents Figure 1 Head Assembly 1 Figure 2 SLX400C Be...

Страница 62: ......

Страница 63: ... Center 6 HC113426 Push Rod Assy Plunger Switch 7 HC141311 Pin Handle 7A HC160581 O ring not shown 8 HC162625 Knob Hand 9 HC120864 Handle Assy Dispense ADA Side HC162629 Knob Ball 3 8 16 THD Black 10 HC120865 Handle Assy Dispense Center ADA HC162629 Knob Ball 3 8 16 THD Black 11 HC196192 Nozzle Serrated Six Point Includes all items above except 6 and 8 Not Shown HC114341 05 Stud Assy Cylinder 3 5 ...

Страница 64: ...2 SLX400C Beater Shaft Assembly Item Part No Description 1 HC196297 Bar Breaker 2 HC121139 Shaft Assy Beater 3 HC141236 Blade Scraper Non Rev 4 HC160557 Seal Beater Shaft 5 HC137593 Washer Double Shaft Seal Can be ordered together HC115525 Seal Assy Shaft Double ...

Страница 65: ...be Assembly Item Part No Description HC121076 01 Tube Assy Mix Feed Complete Short SLX400 1 HC196603 01 Tube Rear Mix Feed Short SLX400 2 HC196604 01 Regulator Mix Feed Short SLX400 3 HC196608 01 Insert Mix Feed Tube Short SLX400 4 HC160502 O ring Includes items 1 through 4 ...

Страница 66: ...50244 Capacitor Run 2 HC150594 Stop Terminal Block End 3 HC150076 Contactor 3P 25A 24V Coil BF25 4 HC1150591 Block Terminal 5 HC150999 Anchor DIN Rail 6 HC150031 Socket Miniature Relay DPDT EMC 7 HC150032 Relay Miniature DPDT 230V AU EMC 8 HC150034 Clip Miniature Relay Retaining EMC 9 HC150276 01 Transformer 75VA 24VAC MURD ...

Страница 67: ...2 HC151702 Board PC Relay 3 HC118095 Switch Assy Plunger 4 HC150993 Membrane Switch Covering 5 HC150708 Switch Disconnect Model SLX500 Only 5A HC151709 Knob Rotary Disconnect Model SLX500 Only 5B HC150046 Switch Toggle 3PST 2HP 6 HC150994 02 Board PCB UI Not Shown HC150000 02 Harness Wire UI HC150000 05 Harness Wire Low Voltage ...

Страница 68: ...ssy Plunger Side LH Complete 1 HC114174 Guide Assy Push Rod 2 HC140701 Plate Switch 3 HC150477 Switch Roller Actuator SPDT 4 HC159912 Screw HXHM 1 4 20 x 2 1 4 ZN 5 HC160104 Nut HEX 1 4 20 ZN 6 HC160381 Screw SKHC 6 32 x 1 BKOX 7 HC160393 Washer Flat 6 Brass 8 HC162323 Spring Compression MW ZN Includes items 1 through 8 ...

Страница 69: ...rip Assy W EF Decal 6 HC196270 Tray Drip 22 Inch Black 7 HC140936 Insert Drip Tray 8 HC121532 Panel Assy Front 9 HC121517 Diverter Assy Air 10 HC141454 Panel Side LH Panel Decals Labels Part No Description HC164034 Beater Installation HC165025 04 Beater Warning Black HC165025 03 Beater Warning Twist HC164221 Cleaning Instruction HC165126 Panel Removal HC169053 Ventilation 6 RR HC141304 03 Decal Wi...

Страница 70: ...8 184582 01 ELECTRO FREEZE Soft Serve Models SLX400C Figure 8 Assembly View ...

Страница 71: ...n 11 HC155709 Valve Hot Gas Bypass 12 HC155398 Valve EPR 13 HC151152 Motor 1HP 208 230 1 60 Bluffton 14 HC155146 Condenser Air 20x18 15 HC153175 Belt V 16 HC151723 Transducer Refrig Pressure 0 500 PSIG 17 HC141237 Bracket Reducer Mounting 18 HC153376 Reducer Gear STM UI 50 FB LH 7 1 or HC153386 Reducer Gear STM UI 50 FB RH 7 1 19 HC121200 Coupling Assy 7 8 Drive 20 HC121370 Shroud Assy Bellmouth C...

Страница 72: ...T w o brake HC184294 Chart O ring EF Gravity SS Laminated HC196298 Cover Hopper HC158012 Handle Brush Fiberglass Brush p n HC158009 HC158000A Lubricant Petro Gel 4 oz tube HC196185 Nozzle Serrated Six Point HC150736 Nut Lock Conduit 1 1 4 Casters HC158013 Sanitizer Stera Sheen Sample HC158014 Sanitizer Stera Sheen Per case 4 jars HC158014A Sanitizer Stera Sheen Per 4 lb jar HC158049 Scale Overrun ...

Страница 73: ...ELECTRO FREEZE Soft Serve Models SLX400C 184582 01 11 O Ring Chart ...

Страница 74: ...12 184582 01 ELECTRO FREEZE Soft Serve Models SLX400C ...

Отзывы: