![ELECTRO FREEZE SLX400 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/electro-freeze/slx400/slx400_operators-manual-with-replacement-parts-list_2379661012.webp)
4
184584
ELECTRO FREEZE Soft Serve Models SLX400, SLX400E, SLX500
CAUTION
To prevent accidental
electrical shock, a positive
earth ground is required.
1. Freezer requires one power supply.
Always check the data plate for proper fuse
size, wire ampacity, and electrical specifi-
cations.
2. Refer to the wiring diagram provided
for proper power connections.
3.
Electrical connections for
models SLX500 and SLX400
are made in
a junction box. Facing the front of the
freezer it is located behind the right side
panel towards the back and bottom of the
frame.
4.
The Model SLX400E
is supplied
with a cord an a NEMA 6-20P plug that
plugs into a 6-20R receptacle. See Figure
2-3.
2.5
Electrical Connections
4. Use a flexible connection when
permissible. Copper wires are required for
connection to freezer. All materials and
connections must conform to local codes
and/or the National Electrical Code.
5. For all 3 phase freezers, beater
shaft rotation must be clockwise as viewed
from the front of the freezer.
3. Supply voltage must be within
±10% of voltage indicated on the nameplate.
4. An easily accessible main power
disconnect must be provided for all poles of
the wiring to the freezer.
2.4 Electrical Requirements - Model SLX400E ONLY
CAUTION
To prevent accidental
electrical shock, a
receptacle with a positive
earth ground is required.
1. Always verify electrical specifica-
tions on the data plate (figure 4-1) of each
individual freezer. Data plate specifications
will always supersede the information in
this manual.
2. This freezer requires a protected 20
amp 220 volt circuit. Connect the freezer to
a circuit separate from any other electrical
equipment. The freezer plug will fit a NEMA
6-20R receptacle. See figure 2-3.
Figure 2-3
Plug