Operator's Manual
with Replacement Parts List
H.C. Duke & Son, LLC
P/N 184584 June 14, 2013
Printed in USA
SOFT SERVE
TWIST MODEL
S
LX400, SLX400E,
SLX500
184584 6/14/13
Страница 1: ...Operator sManual with Replacement Parts List H C Duke Son LLC P N 184584 June 14 2013 Printed in USA SOFT SERVE TWIST MODEL SLX400 SLX400E SLX500 184584 6 14 13 ...
Страница 2: ...Operator s Manual for the Electro Freeze Model SLX400 SLX400E and SLX500 Soft Serve Freezers All contents Copyright 2013 H C Duke Son LLC 2116 Eighth Avenue East Moline Illinois 61244 ...
Страница 3: ...the safety alert symbol but the message is the same Decals with the words DANGER WARNING or CAUTION appear on the freezer DANGER identifies the most serious hazard Decals with the words DANGER or WARNING are typically near specific hazards on the freezer General precautions are listed on CAUTION safety decals In this manual CAUTION messages with the safety alert symbol call attention to safety mes...
Страница 4: ...information and illustrations on pages iv and v of this manual to identify the decal and contact your local distributor or H C Duke Son LLC DO NOT attempt to operate the freezer until you read and understand all safety messages and the operating instructions in this manual DO NOT allow untrained personnel to maintain or service this machine Failure to follow this instruction may result in severe p...
Страница 5: ...ns and operating instructions in this manual are read and understood Take notice of all warning caution instruc tion and information decals or labels on the freezer as shown in the figure to the right The labels have been put there to help maintain a safe working environment The labels have been designed to with stand washing and cleaning All labels must remain legible for the life of the freezer ...
Страница 6: ... with dispense head removed Before removing dispense head 1 Turn all control switches to OFF and 2 Disconnect all power supplies Unit may have more than one power supply Located behind the head 2 Safety Decal Locations continued WARNING Hazardous moving parts Machine starts automatically Do not operate with panel removed P N 165126 2 ...
Страница 7: ...ns 4 3 Specifications 5 3 1 Particulars 5 3 2 Data Plate 6 3 3 ReferenceInformation 6 3 4 InstallationDate 7 3 5 Dimensions 7 4 Virtual Quality Management System VQM Terminology 8 5 Part Names and Functions 10 6 Operator Controls Indicators 13 6 1 Freezer Symbol 14 6 2 Left Side Controls 14 6 3 Indicates Mode of Operation 14 6 4 OFF Indicator 14 6 5 Functionsbuttons Four 14 6 6 Information Window ...
Страница 8: ...1 8 3 CleaningInstructions 23 9 Assembly 25 10 Start up Instructions 28 10 1 Sanitizing 28 10 2 Priming 30 10 2 1 StandardPrimingInsturctions 30 10 2 2 PrimingInstructions 31 11 Closing Procedures 32 11 1 NightSwitchOperation 32 11 2 DrainingProduct 33 12 Soft Serve Information 34 12 1 Overrun 34 12 2 Rerun 34 13 Routine Maintenance 35 14 Troubleshooting Tables 39 PART II REPLACEMENT PARTS with IL...
Страница 9: ...el SLX400 SLX400E andSLX500freezers Make sure all personnel responsible for equipment operation completely read and understand this manual before operating the freezer When properly operated and maintained the freezer will produce a consistent quality product If you require technical assistance please contact your local authorized Electro Freeze Distributor as follows Name Address Phone For factor...
Страница 10: ... transit If the SHOCKWATCH label indicates red and or the carton is broken torn or punctured note the damage on the carrier s freight bill and notify the carrier s local agent immediately 1 Remove the carton from the pallet and move the machine as close as possible to the permanent location 2 Remove the shipping bolts on the bottom of the freezer figure 2 1 and install either the legs or casters f...
Страница 11: ... and water waste connection The connections are found on the bottom under the compressor mounting area They are tagged Water Inlet and Water Waste Amanual shut off valve should be installed in the water inlet line at the time of installation The water pressure must be between 35 140 psig 241 965 kPa for proper operation 6 Place the freezer in its final location and adjust the legs or casters so th...
Страница 12: ...red for connection to freezer All materials and connections must conform to local codes and or the National Electrical Code 5 For all 3 phase freezers beater shaft rotation must be clockwise as viewed from the front of the freezer 3 Supply voltage must be within 10 of voltage indicated on the nameplate 4 An easily accessible main power disconnect must be provided for all poles of the wiring to the...
Страница 13: ...w Cooling 2 1 kw Cooling 2 1 kw Cooling HopperCompressor 1 10 HP 500 BTU hr 1 10 HP 500 BTU hr 1 10 HP 500 BTU hr Beater Motor 2 2 HP 1 5 kw 2 1 HP 0 75 kw 2 1 HP 0 75 kw Refrigerant Cylinder R 404a R 404a R 404a Refrigerant Hopper R 134a R 134a R 134a Charge Cylinder lbs kg A C 4 4 2 0 4 1 81 4 1 81 Charge Cylinder lbs kg W C 3 75 1 7 3 4 1 54 3 4 1 54 Charge Hopper oz kg 7 2 7 2 7 2 Cooling Air ...
Страница 14: ...ers encircled below correspond to the callout numbers in figure 3 1 1 ModelNumber _________________ 2 SerialNumber __________________ 3 Electrical Spec Voltage ________ Phase _______ Hertz _________ 4 Max Fuse Size __________________ 5 Min Circuit Ampacity ___________ 3 2 Data Plate The data plate provides important information that the operator should record and have available for parts ordering ...
Страница 15: ... the date of installation and the name address and phone number of the installer in the space provided below This information will be needed when ordering parts or service for the freezer Date of installation ____________________________________ Installed by ____________________________________ Address ____________________________________ ____________________________________ Phone ________________...
Страница 16: ... timer used for the compressor when the unit is in idle mode no product being drawn Idle Run Comp Range 0 to 12 seconds Idle When the unit is cycling on temperature and no product is being dispensed Lock outs Allows the function of a specific feature button to be temporarily disabled to deter unnecessary usage of that feature Main P C Board Main Control board for the unit housed behind the trim st...
Страница 17: ...necessary Temp Comp Range 10 to 15 F Temperature Offset A function that allows temperature adjustment to the operator Adjustable from 1 9 and 5 being neutral no change Lower than 5 colder and greater than 5 warmer U I User Interface The board that lies directly behind the membrane switch on the front panel This board houses the LED screen that displays the menus and operations The membrane switch ...
Страница 18: ...E SERRATED Forms the frozen product as it is dispensed 1 HEAD DISPENSE Encloses the freezing cylinder and provides an opening for product to be dispensed 2 O RINGS HEAD Seals the head to the freezing cylinder Must be lubricated 3 PLUNGERS DISPENSE SIDE Seals the product opening in the head when closed Allows product to flow when open 4 O RINGS PLUNGER Seals the plunger in the head Must be lubricat...
Страница 19: ...rre sponds to the number in the figure SEAL BEATERSHAFT Sealstheopeningbetweenthe freezingcylinderandthebeatershaft Consistsofthefollowing 4 SEAL BEATERSHAFT 5 WASHER DOUBLESHAFT SEAL 1 BAR BREAKER Keepsproductblendedinthecenter ofthebeatershaft 2 SHAFT ASSY BEATER Rotatesinthefreezingcylinder blendingairandmix Ejectsproduct whendispensingplungerisopened 3 BLADE SCRAPER Scrapesthefrozenproductfrom...
Страница 20: ...d airintothefreezingcylinderfromthe hopper 2 REGULATOR Providesadjustmentonmixfeedrate andapositiveshut offofmixflowto thefreezingcylinder 3 O RING TUBE Sealstheopeningbetweenthehopper andmixfeedtube O ringsdonot needlubrication The following descriptions refer to figure 5 3 The number preceding the part name corre sponds to the number in the figure REGULATOR O RING MIX FEED TUBE ...
Страница 21: ... describe the operator controls Refer to Fig 6 1 for numbered items in description Note the left side controls operates the left side cylinder and hopper Operation for right side controls is the same The display window has three levels of display Opera tors Menu Technician Menu and Factory Menu The last two menus are restricted and reserved for use by qualified personnel CAUTION Test operation of ...
Страница 22: ...e damaged c Night This is the indicator when Night button is pressed In this mode an energy saving feature will activate and reduce product refrigeration The freezer will automatically cycle to maintain temperatures in the cylinder and hopper below 41 F and keep product from deteriorating Use this position when the freezer will not be in use for periods of more than one hour 6 4 OFF Indicator 4 Wh...
Страница 23: ... display to main screen 6 10 Off Button 10 Press OFF button to return to main screen display and turn left side of the freezer off 6 11 Left Side Beater ON Button 11 Pressing this button to turn left side beater ON 6 12 Left Side Beater OFF Button 12 Press this button to turn left side beater OFF 6 13 Arrow Buttons 13 Used by technicians for programming an setting changes See Troubleshooting secti...
Страница 24: ...eed 3 The largest indent setting will allow the least overrun The smallest indent setting will allow the most air in the cylinder and is used for a higher overrun During periods of idle or night operation place the mix inlet port to the closed position At this setting mix and air flow are shut off to the cylinder Important If product is dispensed when the regulator is in the CLOSED posi tion a fre...
Страница 25: ...select SEL button to enter the sub menu Product Type and Temperature Offset will be shown for left and right barrel Use the Arrow Buttons to move the cursor to highlight the value to be changed once highlighted press the select button and the cursor will now be blinking While the cursor is blinking the value may now be changed using the left or right Arrow Buttons once you have reached the desired...
Страница 26: ...rrors Displays active errors for the left or right systems Ablank screen means currently no errors are present Lockouts Allows the operator to lock out the clean freeze and night function so that on the home screen when the button is pressed the unit will not react Operator can select Yes or No to lockout the following functions FreezeMode Y or N CleanMode Y or N NightMode Y or N Operator s Menu O...
Страница 27: ...the Real Time Clock and current date in the unit Last Clean Displays the last time the unit has been cleaned Software Versions Has current software version numbers for both the U I and Main board Main ________ U I _________ Exit Press Exit button to escape any screen Your freezer has the ability to record a cleaning cycle event In order to accomplish this the following conditions must be met A The...
Страница 28: ...with the freezer are necessary for cleaning sanitizing and disassembly assembly 1 HC150009 BRUSH HC158012 HANDLE 4 inch diameter with 36 inch handle used for cleaning the cylinder 2 HC158077 BRUSH 9 16 inch with 36 inch handle used for cleaning the drain tube 3 HC158003BRUSH Double end 1 1 8 inch diameter and 7 16 inch diameter used for clean ing the mix inlet tube mix feed tube head and general c...
Страница 29: ... disassemble and sanitize at the end of every day of operation Figure8 2 continued 1 If there is product in the freezer refer to Section 11 Closing Procedures 11 2 Draining Product 2 Remove plunger rods 6 figure 8 2 by lifting up and swinging the bottom out and down 3 Remove the hand knobs 8 and gently pull the dispensing head 1 straight out 4 Remove the beater shaft 1 figure 8 3 from each cylinde...
Страница 30: ... nozzles 11 Remove head o rings 2 and the o rings from plungers 4 5 Removehoppercover driptrayand insert 6 Remove the mix feed tube figure 8 4 from the hopper Caution To prevent bacteria growth remove all O rings when cleaning Failure to do so could create a health hazard 7 Remove the O rings 3 from the mix feed tube 1 Remove the regulator 2 from the mix feed tube Figure8 4 REGULATOR O RING MIX FE...
Страница 31: ...laundry bleach These materials may contain high concentrations of chlorine bleach and will chemically attack freezer components NOTE The sanitizer should be mixed according to the manufacturer s instructions to yield 100 parts per million PPM available chlorine solution example Stera Sheen Green Label Use warm water 100 to 110 F or 38 to 43 C to wash rinse and sanitize Make sure the sanitizer is m...
Страница 32: ...gent thoroughly brush a the hoppers and the mix feed tubes from the hopper to the cylinders figure8 9 b the inside of the cylinders making certain to clean the back walls with 4 diameterbrushprovided c the inside of the drain tube figure 8 10 Dip the brush in the dish detergent solution and force brush into the drain tube until it stops repeat until clean 6 Repeat step 5 using a brush to rinse wit...
Страница 33: ...ft seal install the cup seals on the plastic washer as shown in figure 9 1 3 Apply a moderate amount of approved sanitary lubricant such as Petrol Gel to the beater shaft as shown in figure 9 2 Install the shaft seal over the rear of the beater shaft figure 9 2 Do not allow any lubricant to come in contact with the bell shaped rubber portions of the shaft seal 4 Apply lubricant to the bearing area...
Страница 34: ... the sides and the longest handle 10 in the center Lock in place with the handle pin 7 Important Excessive force will damage the head Do not use tools to tighten 11 Install the dispensing head onto the freezer by aligning the studs with the holes in the head and sliding toward the freezer Tighten hand knobs evenly finger tight only 12 Install the plunger rods 6 The nozzles 11 will be installed on ...
Страница 35: ...ELECTRO FREEZE Soft Serve Models SLX400 SLX400E SLX500 184584 27 Figure9 5 Mix Feed Tube Assembly 9 Assembly continued 14 Re install drip tray and insert on the freezer REGULATOR O RING MIXFEED TUBE ...
Страница 36: ...rs of sanitizing solution for each hopper The sanitizing solution must be mixed accord ing to manufacturer s instructions to yield 100 PPM parts per million available chlorine solution example Stera Sheen GreenLabel Usewarmwater 100 110 F or 38 43 C to wash rinse and sanitize Make sure sanitizer is mixed thoroughly and has completely dissolved Figure 10 2 Sanitize hopperanditscomponents continued ...
Страница 37: ...izing solution press the and BEATER ON for both sides of the freezer and allow the beaters to run for 5 minutes During this time period check for leaks around the head plungers and drain tubes 8 Press BEATER OFF on both sides Place an empty container under the dispensing head and drain the sanitizing solution by opening the plungers to allow cylinders and hoppers to empty Open and close each plung...
Страница 38: ... Proceed to instructions in section 10 2 1 or 10 2 2 depending on freezer setup REGULATOR O RING MIX FEED TUBE MIX INLET PORT 1 Place a bucket under the dispense head 2 While filling the mix hopper with one gallon of mix open the plunger by pulling the dispense handle down and allow mix to push out remaining sanitizer When pure mix is flowing from the dispense head close the dispense handle figure...
Страница 39: ... dispense head close the dispense handle figure 10 4 Reinstall the actuator rod Important Failure to completely remove sanitizer or water from the freezing cylinder before placing in freeze will damage the freezer 3 Press the freeze button to start the freezer 4 Repeat Steps 1 3 for the other side of the freezer 5 Sanitize and install nozzles 10 2 2 Priming Instructions for Freezers Built into a W...
Страница 40: ...ces with soap and water Use sanitizing solution in a spray bottle and brush to clean the bottom of the plunger openings 4 Turn the mix feed regulator to the CLOSED position 5 Check mix level in hopper to ensure that there is enough mix to keep the indicator light off add mix if necessary Do not dispense product when the mix feed regulator is in the CLOSED position 6 To start the machine after usin...
Страница 41: ...r under the dispensing head and drain the solution by opening the plunger to allow cylinder and hopper to empty 14 When the sanitizing solution has drained from the freezer press BEATER OFF Place the power switch to the OFF position 15 Proceed to disassembly cleaning and sanitizing instructions Figure 11 2 Sanitize hopper Note It is your responsibility to be aware of and conform to the requirement...
Страница 42: ...n percentage Weight of liquid mix minus weight of frozen product divided by the frozen weight Multiply by 100 See example Example Weight of 1 pint of mix 18 oz Weight of 1 pint frozen product 12 oz Difference 6 oz 6 oz divided by 12 oz 5 5 x 100 50 overrun Your Electro Freeze Distributor can provide a scale P N HC158049 that is graduated in overrun percentage 12 2 Rerun 4 Once a week run the mix a...
Страница 43: ... exterior surfaces of the freezer to remove any splattered mix 5 Check overrun and temperature of the product Electro Freeze recommends the following schedule to help maintain your freezer in like new operating condition Take the time to learn and perform these routine procedures and receive in return many years of valuable service from your freezer Protect your investment WEEKLY 1 Carefully inspe...
Страница 44: ...position CAUTION Moving parts DO NOT place hands in the freezing cylinder Severe personal injury could result 6 Look inside the freezing cylinder toward the rear the drive shaft coupling should NOT be turning Turn the switch OFF and disconnect the main power supply 7 If the drive shaft coupling is turning or you are unable to determine whether or not the shaft is turning turn the switch to the OFF...
Страница 45: ...4 Contact your Electro Freeze Dis tributor to check water cooled condenser and flush clean to remove scale and deposits if necessary SEMIANNUALLY 1 Contact your Electro Freeze distributor to replace drive belts 2 Onaircooledandaircooledremotefreez ers have your Electro Freeze distributor check the condenser fan motor oil 2 Have the gear reducer oil changed by your Electro Freeze distributor NOTE U...
Страница 46: ...have condenser fins cleaned by an autho rized service technician 7 On water cooled freezers disconnect the water supply Use compressed air to blow out all remaining water in the condenser Important The water valve must be opened in order to blow out the condenser Failure to purge the freezer of water can result in severe damage to the refrigeration system Call your Electro Freeze Distributor for s...
Страница 47: ... is disconnected Some freezers have more than one disconnect switch Important Some refrigerants are hazardous to the Earth s atmosphere To protect our environment use a refrigerant recovery recycling unit when removing refrigerant from the system THIS SAFETY ALERT SYMBOL IDENTIFIES IMPORTANT PERSONAL SAFETY MESSAGES IN THIS MANUAL WHEN YOU SEE THIS SYMBOL BE ALERT TO THE POSSIBILITY OF PERSONAL IN...
Страница 48: ...ure cut out control 4 Contact your Electro Freeze distributor for service 5 Disconnected or broken wire in electrical circuit 5 Contact your Electro Freeze distributor for service PROBLEM PROBABLE CAUSE REMEDY Compressor does not operate or operates improperly 1 Faulty contactor 1 Contact your Electro Freeze Distributor for service 2 Disconnected or broken wire in switch 2 Contact your Electro Fre...
Страница 49: ...otation to clockwise as viewed from the front of the freezer Dispensed product too hard 1 Controls are set too cold 1 Contact your Electro Freeze distributor for service 2 Plunger switch electrically or mechanically stuck closed 2 Contact your Electro Freeze distributor for service 3 Low suction pressure 3 Contact your Electro Freeze distributor for service Dispensed product too soft 1 Dirty or bl...
Страница 50: ...t of adjustment or defective 2 Contact your Electro Freeze distributor for service 3 Starter points stuck 3 Contact your Electro Freeze distributor for service 4 Suction pressure too low 4 Contact your Electro Freeze distributor for service 1 Trouble in compressor condensing circuit 1 See Troubleshooting Chart Compressor Condensing Circuit Section 16 1 2 Faulty start capacitor run capacitor or rel...
Страница 51: ...t installed 1 Install head assembly 2 Magnetic head switch defective 2 Contact your Electro Freeze Distributor for service 3 Loose connection in control circuit 3 Contact your Electro Freeze Distributor for service 4 Open starter coil 4 Contact your Electro Freeze Distributor for service 5 Faulty capacitor assembly Single phase only 5 Contact your Electro Freeze Distributor for service Beater moto...
Страница 52: ...reeze Distributor for service 3 Restricted water cooled condenser water cooled models 3 Contact your Electro Freeze Distributor for service 4 Dirty air condenser air cooled models 4 Contact your Electro Freeze Distributor for service 5 Unit location too warm air cooled models 5 Contact your Electro Freeze Distributor for service 6 Refrigerant overcharge 6 Contact your Electro Freeze Distributor fo...
Страница 53: ... Occurs when hopper system run time exceeds 45 minutes Disconnect unit main power and restore 1 Dirty condenser 2 Shortage of refrigerant 3 Moisture in system 4 Compressor failing 5 Faulty thermistor Contact your Electro Freeze distributor for service Barrel Temp Affected Barrel enters night temp cycle mode Barrel Temperature Out Occurs when barrel thermistor is above or below temp limit for 1 min...
Страница 54: ...rvice Motor OVLD Affected barrel enters off mode hopper still operates Motor Overload Open Occurs when motor current is 0 when motor is given an on signal Disconnect unit main power and restore 1 Product too cold 2 Loose wire connection 3 Open starter coil 4 Faulty capacitor 1 ph Only 5 Faulty beater motor 1 Adjust product temperature 2 Contact your Electro Freeze distributor for service Motor Amp...
Страница 55: ... S A QUALITY PARTS PROTECT YOUR EQUIPMENT KEEP YOUR FREEZER IN EXCELLENT CONDITION ALWAYS CONTACT YOUR ELECTRO FREEZE DISTRIBUTOR FOR REPLACEMENT PARTS SOFT SERVE TWIST MODEL SLX400 SLX400E SLX500 184584 01 6 14 13 REPLACEMENT PARTS MANUAL with ILLUSTRATIONS ...
Страница 56: ..._____________ Phone ________________________ If you require any further assistance contact H C Duke Son LLC Electro Freeze as follows Phone 309 755 4553 800 755 4545 FAX 309 755 9858 E mail service electrofreeze com Replacement Parts Orders Table of Contents PART II Figure 1 Head Assembly 1 Figure 2 SLX400 Beater Shaft Assembly 2 Figure 3 SLX500 Beater Shaft Assembly 3 Figure 4 Mix Feed Tube Assem...
Страница 57: ...unger Dispense Center 6 HC113426 Push Rod Assy Plunger Switch 7 HC141311 Pin Handle 7A HC160581 O ring not shown 8 HC162625 Knob Hand 9 HC120864 Handle Assy Dispense ADA Side HC162629 Knob Ball 3 8 16 THD Black 10 HC120865 Handle Assy Dispense CenterADA HC162629 Knob Ball 3 8 16 THD Black 11 HC196192 Nozzle Serrated Six Point Includes all items above except 6 and 8 Not Shown HC114341 05 Stud Assy ...
Страница 58: ...Figure 2 SLX400 Beater Shaft Assembly Item Part No Description 1 HC196297 Bar Breaker 2 HC121139 Shaft Assy Beater 3 HC141236 Blade Scraper Non Rev 4 HC160557 Seal Beater Shaft 5 HC137593 Washer Double Shaft Seal Can be ordered together HC115525 Seal Assy Shaft Double ...
Страница 59: ...Figure 3 SLX500 Beater Shaft Assembly Item Part No Description 1 HC196301 Bar Breaker 2 HC120866 Shaft Assy Beater 3 HC141009 Blade Scraper Non Rev 4 HC160557 Seal Beater Shaft 5 HC137593 Washer Double Shaft Seal Can be ordered together HC115525 Seal Assy Shaft Double ...
Страница 60: ...C121252 01 Tube Assy Mix Feed Complete Short SLX400 HC121252 Tube Assy Mix Feed Complete Long SLX500 1 HC121251 01 Tube Rear Mix Feed Short SLX400 or HC121251 Tube Rear Mix Feed Long SLX500 2 HC141334 01 Sleeve Rear Mix Feed Short SLX400 or HC141334 Sleeve Rear Mix Feed Long SLX500 3 HC160502 O ring Includes items 1 through 3 ...
Страница 61: ...HC150076 Contactor 3P 25A 24V Coil BF25 Beater Motor 4 HC151704 Board Current Sense SLX Figure 5 Contactor Box Figure 6 Capacitor Box Item Part No Description 1 HC150318 Capacitor Run SLX500 Beater Motor 2 HC150491 Capacitor Run SLX500 Compressor or HC150244 Capacitor Run SLX400 Series Compressor 3 HC160772 Clamp Hose 1 5 16 2 14 Note Model SLX400 Series beater motor capacitors are located on the ...
Страница 62: ...ription 1 HC151701 Board PC Main 2 HC150078 Relay Miniature SPDT 12VDC Coil 2A HC150165 Socket Miniature Relay SPDT 2B HC150166 Clip Miniature Relay Retaining 3 HC118095 Switch Assy Plunger Side LH see Figure 8 4 HC150993 Membrane Switch Covering 5 HC150046 Switch Toggle 3PST 2HP 6 HC150994 Board PCB UI QTY 9 ...
Страница 63: ...witch Assy Plunger Side LH Complete 1 HC114174 Guide Assy Push Rod 2 HC140701 Plate Switch 3 HC150477 Switch Roller Actuator SPDT 4 HC159912 Screw HXHM 1 4 20 x 2 1 4 ZN 5 HC160104 Nut HEX 1 4 20 ZN 6 HC160381 Screw SKHC 6 32 x 1 BKOX 7 HC160393 Washer Flat 6 Brass 8 HC162323 Spring Compression MW ZN Includes items 1 through 8 ...
Страница 64: ...anel View Sheet 1 of 2 Hardware for Panels Panel Screw Nut Speed Spacer Nut Speed on Frame Dispense HC160076 HC159132 n a n a Front HC160076 HC159132 n a HC159067 Rear HC160048 HC160117 n a n a Side HC159219 HC160114 HC138456 n a Trimstrip HC160076 n a n a n a n a Not Applicable ...
Страница 65: ...t Lock Conduit 1 1 4 for Casters 11 HC162105 Caster 1 1 4 St PT w Brake 11A HC150736 Nut Lock Conduit 1 1 4 for Casters 12 HC121190 Panel Assy Front 12A HC199016 Grommet Rubber 5 8 ID Not shown 13 HC140941 Panel Front Louvered 14 HC196270 Tray Drip 22 in Black 15 HC120778 Insert Assy Drip Tray 16 HC120855 01 Trimstrip Assy SST 17 HC141294 Panel Dispense 18 HC141307 Panel Side Not Shown HC150605 Co...
Страница 66: ...10 184584 01 ELECTRO FREEZE Soft Serve Models SLX400 SLX400E SLX500 Figure 10 Assembly View ...
Страница 67: ...KAE SLX400 Series includes compressor and HC199047 Boot Cap Protector HC155638 Bushing HC150244 Capacitor Run HC155054 Drier Filter or HC121256 Compressor Assy 208 230 1 60 ZS15KAE SLX500 includes compressor and HC199047 Boot Cap Protector HC155638 Bushing HC151491 Capacitor Run HC155054 Drier Filter or HC121257 Compressor Assy 208 230 3 60 ZS15KAE SLX500 includes compressor and HC155638 Bushing H...
Страница 68: ... 4 ST PT w o brake HC184294 Chart O ring EF Gravity SS Laminated HC196298 Cover Hopper HC158012 Handle Brush Fiberglass Brush p n HC158009 HC158000A Lubricant Petro Gel 4 oz tube HC196185 Nozzle Serrated Six Point HC150736 Nut Lock Conduit 1 1 4 Casters HC158013 Sanitizer Stera Sheen Sample HC158014 Sanitizer Stera Sheen Per case 4 jars HC158014A Sanitizer Stera Sheen Per 4 lb jar HC158049 Scale O...
Страница 69: ...ELECTRO FREEZE Soft Serve Models SLX400 SLX400E SLX500 184584 01 13 ...
Страница 70: ...14 184584 01 ELECTRO FREEZE Soft Serve Models SLX400 SLX400E SLX500 ...