12-47
CONTROL SYSTEM
Revision Y06-01
Service Manual - LEX
12B.3.15 Protection
x
When all relays meet their function requirements at the same time, there
should be an interval of 0.5 second between every two relays. The action
procedures are as follows:
ON state:
AHEAT
Æ
RV
Æ
OFAN —> COMP
OFF state:
AHEAT
Å
RV
Å
OFAN
Å
COMP
12B.3.16
Compressor delay protection
x
At startup if the operation mode is not change, compressor will keep on
running during the first 5 minutes, and it will delay for 3 minutes for a re-start
once it was turned off.
x
Compressor starts at 3 minutes delay unless:
x
Power is on for the first time or power off lasts for 3 minutes, COMP has no 3
minutes delay protection;
12B.3.17 RV control
x
In cooling or drying mode or fan mode, RV is off.
x
In heating mode, RV will turns on.
x
Switching between heating mode to other modes, or shutting off in heating
mode, RV delays 2 minutes before turning off.
12B.3.18 5 Diagnostic
x
If MCU detect that one of the sensors RT, ICT or, OCT is blow -40ºC or over
85ºC, the sensor is invalid and will be indicated (see 3.13).But the air-
conditioner operates continuously.
x
In Cooling or Heating mode, COMP turns on for 20 minutes and turns off for 5
minutes, it is continuously cycle by cycle. In Dry mode, COMP turns on for 10
minutes and turns off for 6 minutes.
x
If RT is invalid, system runs at cycle by cycle mode.
x
If OCT and ICT are invalid, system runs at cycle by cycle mode too.
x
For cooling only unit’s type, if ICT is wrong, system runs at cycle by cycle
mode.
Содержание LEX 12
Страница 36: ...9 1 ELECTRICAL CONNECTIONS Revision Y06 01 Service Manual LEX 9 ELECTRICAL CONNECTIONS 9 1 LEX 7 9 12 14 R410A ...
Страница 38: ...10 2 REFRIGERATION DIAGRAMS Revision Y06 01 Service Manual LEX 10 1 2 LEX 9 12 14 R410A ...
Страница 91: ...14 3 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 3 Outdoor Unit ONG 7 9 12 ST ...
Страница 95: ...14 7 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 7 Outdoor Unit ONG 14 ST ...
Страница 97: ...14 9 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 9 Outdoor Unit ONG 7 RC ...
Страница 99: ...14 11 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 11 Outdoor Unit ONG 9 12 RC ...
Страница 102: ...14 14 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 14 Outdoor Unit ONG 14 RC ...
Страница 106: ...15 3 OPTIONAL ACCESSORIES Revision Y06 01 Service Manual LEX 15 3 RCW RCW2 Wiring Connections as Shown on Kit ...
Страница 108: ......