12-3
CONTROL SYSTEM
Revision Y06-01
Service Manual - LEX
12.4
General
functions
12.4.1
COMP
operation
For each Mode including POWER OFF & SB, a Min time delay of 3 min
before COMP restarting, excluding DEICING Mode
The Min operation time of COMP under different operating conditions is
Operation Mode
Min operation time of
COMP
Heat, Cool or Auto Modes
3 min.
Fan, Dry, Overflow, Protection modes, or mode change
ignored
12.4.2 IFAN
operation
•
Min time interval between IFAN speed change in AUTOFAN Mode, is 30 sec.
•
Min time interval between IFAN speed change in H/M/L Mode is 1 sec.
•
IFAN speed in Heat/Cool Autofan Mode is determined according to the following table:
Δ
T
IFAN Speed
Δ
T
≥
2
HIGH
2
≥
Δ
T
≥
1
MED
1
≥
Δ
T
LOW
where in
Heat
Mode:
Δ
T = SPT-RT
in Cool Mode:
Δ
T = RT-SPT
Note:
•
In Heat Mode, the rules in section 4.0.3 have the higher priority.
•
The table above can be represent by a hysteresis curve which
will minimize the switching of the IFAN relay and will minimize the
change in IFAN speed:
T [
o
c]
L
M
H
IFAN speed
3
2
1
12.4.3 OFAN
operation
•
Min time interval between OFAN ON/OFF state change is 30 sec.
•
In general, OFAN starts together with COMP.
12.4.4 HE
operation
•
Minimum Heaters ON or OFF time is 30 sec.
•
Heaters can be activated only if IFAN is on.
Содержание LEX 12
Страница 36: ...9 1 ELECTRICAL CONNECTIONS Revision Y06 01 Service Manual LEX 9 ELECTRICAL CONNECTIONS 9 1 LEX 7 9 12 14 R410A ...
Страница 38: ...10 2 REFRIGERATION DIAGRAMS Revision Y06 01 Service Manual LEX 10 1 2 LEX 9 12 14 R410A ...
Страница 91: ...14 3 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 3 Outdoor Unit ONG 7 9 12 ST ...
Страница 95: ...14 7 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 7 Outdoor Unit ONG 14 ST ...
Страница 97: ...14 9 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 9 Outdoor Unit ONG 7 RC ...
Страница 99: ...14 11 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 11 Outdoor Unit ONG 9 12 RC ...
Страница 102: ...14 14 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 01 Service Manual LEX 14 1 14 Outdoor Unit ONG 14 RC ...
Страница 106: ...15 3 OPTIONAL ACCESSORIES Revision Y06 01 Service Manual LEX 15 3 RCW RCW2 Wiring Connections as Shown on Kit ...
Страница 108: ......