21
G[,led brightness level]
Set/display the current LED brightness level.
Send: G,02;
XG3:
nothing
Send: G;
XG3: G,02;
Sets the LED brightness or views the current setting. Valid brightness settings are 0 (brightest), 1, 2, 3
(dimmest).
H
?
Display help screen.
Displays the list of currently supported commands.
Note: additional commands may be added at a
future date.
I
Display current informational status.
Send:
I;
XG3:
I,00146000000,02,11,00,01,00,00,00;
Position
Description
0
Echoed ‘I’ command
1
Current frequency in MHz, represented using 11 digits with leading zeros
2
Current Level: 00 = 0dBm, 01 = -33, 02 = -73, 03 = -107
3
Current band memory: 00 - 11
4
Output: 01 = on, 00 = off
5
PLL Lock: 01 = locked, 00 = unlocked
6-8
Future use
L[,level#]
Set current output level or display current output level.
Valid levels are 0 ,1,2 or 3. 0 = 0 dBm, 1 = -33 dBm, 2 = -73 dBm, 3 = -107 dBm
Send: L,02;
sets output level to -73dBm
XG3: nothing
Send L;
XG3: L,02;
M,location#[,frequency]
Program or view the specified memory location.
Valid memory locations are 0 - 11. Memory location# is a required argument. If no frequency
argument is given, the contents of that memory location will be displayed. Frequencies are entered