background image

 

Customer Service and Support 

Technical Assistance

 

You can send e-mail to 

[email protected]

 and we will respond quickly - typically the same day 

Monday through Friday. Telephone assistance is available from 9 A.M. to 5 P.M. Pacific time (weekdays 
only) at 831-763-4211. Please use e-mail rather than calling when possible since this gives us a written 
record of the details of your problem and allows us to handle a larger number of requests each day.

 

Repair / Alignment Service

 

(We want to make sure everyone succeeds!)

 

If necessary, you may return your Elecraft product to us for repair or alignment. (Note: We offer unlimited 
email and phone support to get your kit running, so please try that route first as we can usually help you 
find the problem quickly.)

  

IMPORTANT:

 

You must contact Elecraft before mailing your product 

to obtain authorization for the 

return, what address to ship it to and current information on repair fees and turnaround times. (Frequently 
we can determine the cause of your problem and save you the trouble of shipping it back to us.) Our repair 
location is different from our factory location. We will give you the address to ship your kit to at the time 
of repair authorization. 

Packages shipped without authorization will incur an additional shipping charge 

for reshipment to our repair depot. 

Elecraft's 1-Year Limited Warranty 

This  warranty  is  effective  as  of  the  date  of  first  consumer  purchase  (or  if  shipped  from  factory,  date  product  is 
shipped  to  customer).  It  covers  both  our  kits  and  fully  assembled  products.  For  kits,  before  requesting  warranty 
service, you should fully complete the assembly, carefully following all instructions in the manual.   

Who  is  covered:

  This  warranty  covers  the  original  owner  of  the  Elecraft  product  as  disclosed  to  Elecraft  at  the 

time of order.  Elecraft products transferred by the purchaser to a third party, either by sale, gift or other method, 
who  is  not  disclosed  to  Elecraft  at  the  time  of  original  order,  are  not  covered  by  this  warranty.  If  the  Elecraft 
product is being bought indirectly for a third party, the third party's name and address must be provided to Elecraft 
at time of order to insure warranty coverage. 

What is covered: 

During the first year after date of purchase, Elecraft will replace defective or missing parts free 

of charge (post-paid). We will also correct any malfunction to kits or assembled units caused by defective parts and 
materials. Purchaser pays inbound shipping to Elecraft for warranty repair, Elecraft will pay shipping to return the 
repaired  equipment  to  you  by  UPS  ground  service  or  equivalent  to  the  continental  USA  and  Canada.  Alaska, 
Hawaii and outside U.S. and Canada actual return shipping cost paid by owner.  

What  is  not  covered:

  This  warranty  does  not  cover  correction  of  kit  assembly  errors.  It  also  does  not  cover 

misalignment;  repair  of  damage  caused  by  misuse,  negligence,  or  builder  modifications;  or  any  performance 
malfunctions involving non-Elecraft accessory equipment. The use of acid-core solder, water-soluble flux solder, or 
any  corrosive  or  conductive  flux  or  solvent  will  void  this  warranty  in  its  entirety.  Also  not  covered  is 
reimbursement  for  loss  of  use,  inconvenience,  customer  assembly  or  alignment  time,  or  cost  of  unauthorized 
service. 

Limitation of incidental or consequential damages:

 

This warranty does not extend to non-Elecraft equipment or 

components  used  in  conjunction  with  our  products.  Any  such  repair  or  replacement  is  the  responsibility  of  the 
customer. Elecraft will not be liable for any special, indirect, incidental or consequential damages, including but not 
limited to any loss of business or profits.

 

Содержание XG3

Страница 1: ...Elecraft www elecraft com 831 763 4211 ELECRAFT XG3 RF SIGNAL SOURCE Owner s Manual E740154 Revision D3 July 26 2017 Copyright 2017 Elecraft All Rights Reserved...

Страница 2: ...2...

Страница 3: ...equency 14 Reverse Power 14 Applications 14 Receiver Testing 15 Receiver Alignment 17 RF Signal Tracing and Troubleshooting 17 VFO LO for Experimentation 17 Updating Firmware 18 XG3 Remote Control Com...

Страница 4: ...ose voltages from reaching the XG3 A fusible trace is provided that may protect the XG3 in the event you accidentally apply voltage or RF power to the RF OUT connector If that happens you may be able...

Страница 5: ...erface RS 232 or USB Allows changing the preset frequencies and operating the XG3 from a personal computer using the XG3 Utility program available free from Elecraft Note For information on writing yo...

Страница 6: ...riginal owner of the Elecraft product as disclosed to Elecraft at the time of order Elecraft products transferred by the purchaser to a third party either by sale gift or other method who is not discl...

Страница 7: ...identally be turned on by flipping the battery over so the battery terminals are facing away from the contacts in the XG3 Note the XG3 has reverse polarity protection in the event you insert the batte...

Страница 8: ...The XG3 is pre programmed with a test frequency in each band as shown below You can change these frequencies using a computer as described below under Computer Controlled Operation BAND FREQ MHz BAND...

Страница 9: ...e from 1 500000 MHz to 1400 000000 MHz by entering it in the CURRENT FREQUENCY window and then pressing Enter on your computer keyboard to transfer the frequency data to the XG3 You don t need to ente...

Страница 10: ...en a sweep is in progress one of the band LEDs on the XG3 will blink The blinking LED will be whichever one was selected last before the sweep was initiated Program a sweep as follows With the XG3 con...

Страница 11: ...y The mark frequency is the current output frequency of the XG3 The complete set of Morse Memory meta characters are listed below Morse Memory Meta characters turn on RTTY mode characters following wi...

Страница 12: ...rig_is_xg3_de_W1AW_73_ XG3 nothing Send the Morse memory Send W XG3 nothing RT character_string immediately sends the character string using RTTY To embed a space use the _ underscore character n for...

Страница 13: ...ndefinitely WM n rRIG_IS_XG3 03 de_w1aw Changes to RTTY and sends LF CR then RIG_IS_XG3 then waits 3 seconds changes to CW and sends de w1aw and then repeats WM QTH_IS_APTOS_CA 95001_ Here is an examp...

Страница 14: ...er a new CALIBRATION FACTOR and click on APPLY send the value to the XG3 Repeat this process until the XG3 output is on the correct frequency Reverse Power Never apply RF power a DC or an AC voltage t...

Страница 15: ...lator with a log function key including the scientific calculator built into most Windows operating systems under Accessories after opening the basic calculator you may have to select View Scientific...

Страница 16: ...20 to obtain the S N N ratio in dB for a 1 microvolt signal 4 If the S N N ratio is greater than 10 dB you can approximate the minimum discernable signal MDS by subtracting the S N N ratio from 107 d...

Страница 17: ...isolate the XG3 from any circuits carrying voltage Avoid injecting large RF signals into the XG3 See Reverse Power on pg 14 When using the XG3 for low level signal injection you may want to couple it...

Страница 18: ...nnector is inserted all the way into the jack on the top of the XG3 To install new firmware in your XG3 click on the utility Send Firmware to the XG3 button to start the transfer and follow the on scr...

Страница 19: ...ry locations 0 to 11 Location 0 is associated with the 160M LED and location 11 is associated with the 2M LED See Y command for list Currently the XG3 has a fundamental frequency range of between 1 5...

Страница 20: ...ent frequency C location Call memory Send C 01 XG3 nothing Send C XG3 C 01 Recalls the passed frequency memory location The output frequency will change and the associated location LED will be illumin...

Страница 21: ...mand 1 Current frequency in MHz represented using 11 digits with leading zeros 2 Current Level 00 0dBm 01 33 02 73 03 107 3 Current band memory 00 11 4 Output 01 on 00 off 5 PLL Lock 01 locked 00 unlo...

Страница 22: ...hown Note the XG3 output is turned on by default Send O 00 turns output off XG3 nothing Send O XG3 O 00 P minutes Set or view the auto power off timer value Allows setting or viewing the auto power of...

Страница 23: ...mand and will terminate the sweep This allows the Info command to be used to determine the current frequency during the sweep See Q command for programming the 2 sweep memories Send S 01 XG3 nothing T...

Страница 24: ...20000 7 020 MHz 30m LED 4 00010120000 10 120 MHz 20m LED 5 00014020000 14 020 MHz 17m LED 6 00018120000 18 120 MHz 15m LED 7 00021020000 21 020 MHz 12m LED 8 00024900000 24 900 MHz 10m LED 9 000280200...

Страница 25: ...186 186 186 186 186 186 186 186 188 186 186 186 186 187 186 186 186 186 186 186 186 186 186 186 186 K Display CS2100 chip ID and revision number Retrieves the CS2100 frequency synthesizer chip identif...

Страница 26: ...ard entry and operation of the unit will be suspended Returned key codes are 001 On Off Key 002 Level Key 003 Band 004 Band When the N command is sent the XG3 will not display anything until a key is...

Страница 27: ...evels of 0 dBm 33 dBm 73 dBm and 107 dBm The RF output is protected from moderately excessive levels by D4 and D18 Power is applied to the MAR6 amplifier only when it is needed to conserve the battery...

Страница 28: ...28...

Страница 29: ...29...

Страница 30: ...hematic Below is the schematic diagram of the optional RS232 serial interface cable A kit of parts to assemble a cable is available from Elecraft order W1SERKT or you can order a factory assembled cab...

Страница 31: ...i CAUTION Use an ESD safe wrist strap or touch a bare metal ground before touching the XG3 pc board A static dissipating mat is recommended 1 Remove the battery cover and battery 2 Remove the four scr...

Отзывы: