3. Additional system capabilities
3.1 Alarm zone inputs and controlled outputs
EXPLANATION
Activated zone can work in three different modes: simple, 24h and fire.
24h mode means that the zone is active and protected round the clock regardless whether the system is engaged or disengaged.
Fire mode is same as 24h except the different audio siren tone which sounds with beeps
3.1.1 System and Zone settings. STATUS
To see the default texts of activated zones and controlled output names as well as their current settings and status send the following
SMS message:
You will receive the answer – two SMS messages. E. g.:
The first SMS message.
The system in ARMED/DISARMED. Z1:ON/OFF Z2:ON/OFF Z3:ON/OFF Z4:ON/OFF Z5:ON/OFF Z6:ON/OFF
C1:CONTROLLER1:ON/OFF C2:CONTROLLER2:ON/OFF
The second SMS message.
Z1:door triggered; Z2:windows triggered; Z3:fire triggered; Z4:motion1 triggered; Z5:motion2 triggered;
Z6:motion3 triggered;
ON- means that appropriate zone is activated, i. e., it will react in the case of alarm. OFF- it is deactivated. If zones were configured for 24
hour mode, then instead of ON it will show 24ON. For fire mode, instead of ON it will show FON.
If controlled output was enabled with timer (see chapter 3.3 for more details), STATUS command will report remaining time for control
-
led output to stay ON or OFF.
E.g. C2:CONTROLLER2:ON:00.01.23
This means that controlled output2 will be ON for 0 hours 1 minute and 23 seconds
The second SMS message indicates the set texts that will be delivered in case of alarm.
3.1.2 Changing alarm texts and controlled output names
Manufacturer set the following alarm texts for the triggered zones and controlled output names: Z1-door triggered, Z2-win
-
dows triggered, Z3-fire triggered, Z4-motion1 triggered, Z5-motion2 triggered, Z6-motion3 triggered, C1-CONTROL1, C2-CON
-
TROL2.
E. g. if in the case of alarm zone Z4 is triggered, the system will send SMS message with the following text: motion1 triggered
Alarm texts can be changed by sending the following SMS message:
E.G. XXXX_Z1:Door intrusion;Z2:Fire sensor triggered;
The texts can be changed all at once for all zones, for several zones or one by one. Text limitation for one zone is 24 characters. The space
equals one symbol. It is necessary to put a semicolon at the end of each new text. As semicolon is used for separating texts for different
zones, it cannot be used in the middle of alarm texts. Also, the texts cannot have the same names as control commands.
Controller names can be changed by sending the following SMS message:
E.G. XXXX_C1:PUMP
Maximum controller name length is 10 characters. Controller names should not contain a semicolon at
the end. Zone names and controller names cannot be changed simultaneously.
XXXX_STATUS
XXXX_Z1:NewAlarmText;Z2:NewAlarmText;Z3:NewAlarmText;Z4:NewAlarmText;Z5:NewAlarmText;Z6:Ne
wAlarmText;
XXXX_C1:NewControllerName_C2:NewControllerName
ESIM 262
0000_
STATUS
ESIM 262
XXXX_
C1:PUMP