3.1.6 Enter and Exit time-out configuration
Alarm System ESIM262 allows configuring first zone timeout in seconds. This allows user to disarm system upon entering or arm system
upon leaving with DALLAS button or keypad. The DALLAS button must be placed into the reader or user must enter PIN code with
keyboard within configured time-out period (manufacturer default 15 sec) otherwise alarm will sound.
When arming alarm system with DALLAS key or using the keyboard it is allowed to leave the premises during the pre-set period (ma
-
nufacturer set 15 sec.).
Time-out period can be configured by SMS message:
Where SSI – first zone entry time-out after activation in seconds. SSO – exit time-out after activation.
There is no time-out if period is set to 0.
E.g. XXXX_INOUT:20:30
means 20 seconds time-out on entry to disable the system and 30 seconds –
time-out to leave house before the system activates.
3.2 DALLAS buttons
WARNING
First DALLAS button can be associated with the system just by touching it to the reader without the need to send any SMS message. The
system will beep twice informing about successful DALLAS button association and button will be saved into non-volatile system memory.
Other DALLAS buttons can be associated by entering special mode via SMS message:
The system will reply with a message stating entry into special programming mode. Then new button can be placed to the reader and
it’s unique code will be recorded by the system. Again successful operation will be notified by double beep. The system allows to asso
-
ciate and save up to five DALLAS buttons.
E.g. The system will save and record every new button until fifth button has been recorded.
When all buttons have been associated and recorded, it’s necessary to send SMS message:
This SMS command will block adding new buttons. Failing to send this SMS message, the system will not accept and respond to DALLAS
buttons. The DALLAS buttons can be erased one a at time or all at once by SMS:
This SMS command will erase all recorded buttons, and new buttons can be added as described above.
3.3 Managing C1 Controller. Timer.
Alarm system ESIM262 has two open-collector controlled outputs C1 and C2. They can be used to control various electrical devices such
as electric pumps, heating, lighting, etc. When outputs C1 or C2 are enabled, it corresponds to output pins being pulled to ground (GND).
Enabling output:
Disabling ouput:
Set controlled output names can be used instead of C1 or C2.
E.g. XXXX_PUMP:OFF
Timer
Alarm system ESIM262 has internal timer clock. This feature allows any controlled output to be switched on or off for a specified time
period. The following SMS command should be sent:
XXXX_INOUT:SSI:SSO
XXXX_IBPROG:ON
XXXX_IBPROG:OFF
XXXX_C1:ON
XXXX_C1:OFF
XXXX_RESETIB
ESIM 262
XXXX_IN
OUT:20:30
Содержание ESIM262
Страница 1: ...GSM APSAUGOS IR VALDYMO SISTEMA GSM ALARM AND MANAGEMENT SYSTEM GSM ELDES ALARM ESIM262 LT EN RU...
Страница 50: ...U ra ams...
Страница 51: ......
Страница 52: ...Pagaminta Lietuvoje Made in Lithuania www eldes lt...