7.4.1. Zone numbering
The zone numbers ranging from Z1 through Z2 are permanently reserved for on-board zones. The Z3-Z34 zone
numbers are automatically assigned to the created virtual zones and the wireless devices connected to the
system in the chronological order.
7.4.2. Zone expansion
For additional detection device connection, the number of zones can be expanded by:
•
pairing wireless devices (see section
3. HOW TO MANAGE THE WIRELESS DEVICES
).
•
creating virtual zones (see
ELDES Configuration Tool
software’s Help section).
The maximum supported number of zones is 34.
7.4.3. Zone type definitions
•
Interior Follower
– The zone can be violated during exit and entry delay without causing an alarm. If
the zone is violated before the entry delay has begun, it will cause an instant alarm followed by single
notification delivery even if the zone has been violated multiple times or another Interior Follower-type
zone has been violated while alarm period (by default - 1 minute) is in progress. Typically, this zone is
used for indoor protection devices, such as motion detectors, installed close to the exit/entry doors.
•
Instant
– The alarm is instantly caused if this zone is violated. After each alarm notification will be
sent to user. This zone type is usually used for windows or other zones, and shock detectors.
•
24-Hour
– When the system is either armed or disarmed, the zone will cause instant alarm if
violated. Normally, this type of zone is used for securing the areas that require constant supervisory.
•
Delay
– This zone type can be violated during exit and entry delay without causing an alarm. If the
zone is violated when the system is armed, it will initiate entry delay countdown intended for the user
to disarm the system. If the zone is left violated after the exit delay expires, it will cause an instant
alarm. Typically, this zone type is used for door contacts installed at designated exit/entry doors
•
Fire
– If this zone type is violated when the system is either armed or disarmed, the alarm will be
instantly caused and the siren will emit pulsating sound. Typically, this zone type is used for flame
and smoke detectors.
•
Panic/Silent
– This zone operates the same as 24-Hour zone type, but the system will not activate
the siren and keypad buzzer if violated. Normally, this zone type used for panic alarm buttons.
NOTE:
The system will NOT activate siren and keypad buzzer only when Panic/Silent zone type is
violated.