MOTOR PUMP OPERA-

TING SPEED IS DISPLA

-

YED.

PUMP WATER

PRESSURE 

      

IS DISPLAYED

.  

ENGINE WATER OR OIL

TEMPERATURE IS

DISPLAYED.

ENGINE OIL 

PRESSURE

IS DISPLAYED.

THE CALL IS 

PRESENT.

THE ENGINE 

IS RUNNING.

PUMP PRIMING 

(ALWAYS ON) 

FAILURE TO 

PRIME PUMP 

FLASHING.

THE FUEL LEVEL

IS  DISPLAYED.

THE VOLTMETER 

OF THE BATTERY IS 

DISPLAYED.

ACCUMULATED

OPERATION HOURS

ARE DISPLAYED.

PRESS TO ACCELERA

-

TE THE MOTOR PUMP 

WHEN THE CONTROL 

UNIT IS IN MANUAL 

MODE.

PRESS TO DECELERA

-

TE THE MOTOR PUMP 

WHEN THE CONTROL 

UNIT IS IN MANUAL 

MODE.

EMERGENCY STOP

PRESS TO ADJUST

ELECTRONIC PUMP 

WATER PRESSURE 

SWITCH.

THE BATTERY IS

NOT CHARGING.

LOW ENGINE

OIL PRESSURE

THE ENGINE PROTEC-

TION DEVICES ARE 

ACTIVE. SWITCHED  

ON 10 SEC. AFTER 

DETECTION OF ENGINE 

RUNNING

.

FIELD SIGNAL 

STRENGTH

CAN BUS PARAME

-

TERS

SMS MESSAGE 

BEING

RECEIVED OR SENT.

SYSTEM ERROR.

MISSING SIMCARD.

PROCEDURES FOR 

DISABLING

THE PIN CODE, NOT 

REGULAR.

PUMP PROTECTION

IS ACTIVE.

PRESS TO SELECT 

THE DISPLAYED 

FUNCTION, EACH 

TIME IT IS PRESSED, 

THE INSTRUMENT 

INDICATED BY THE

DISPLAY CHANGES. 

HOLD DOWN TO SI

-

LENCE THE GENERAL 

ALARM (BUZZER).

PRESS UNTIL THE 2

SIGNS START 

FLASHING

TO EXCLUDE PUMP

PROTECTION.

TO RE-ACTIVATE

PROTECTION, PRESS

AGAIN UNTIL THEY

SWITCH OFF.

PRESS TO START 

THE MOTOR 

PUMP WHEN THE 

CONTROL UNIT 

IS IN MANUAL 

MODE.

PRESS BRIEFLY, 

THE LED STAYS 

OFF, THE MOTOR 

PUMP STOPS IF 

THE CALL OR THE 

TIMER ARE NOT 

ACTIVE.
PRESS UNTIL THE 

LED FLASHES, 

THE MOTOR PUMP 

STOPS AND STAR

-

TING WITH THE 

CALL AND THE TI

-

MER IS SWITCHED 

OFF.

STOPPAGE DUE 

TO LOW PRESSURE OR

PUMP WATER 

OVERPRESSURE OR

ELECTRONIC

PRESSURE SWITCH

(TRANSMITTER) INTERRUPTED.

IN THIS CASE, THE ANOMALY IS

HIGHLIGHTED BY THE FLASHING

WARNING LIGHT.

OVERPRESS.

DISCONN’ED

LOW PRESS..

STOPPING DUE TO LOW

FUEL LEVEL

NORMAL WORKING 

PRESSURE. SWITCHED 

OFF WHEN THE PRES

-

SURE DIFFERS FROM 

THE WORKING PRES

-

SURE BY THE ALLOWED 

OSCILLATION.

UTILIZE IN 

PROGRAMMING.

STOPPING DUE TO

INSUFFICIENT

ENGINE OIL PRESSURE

STOPPING DUE TO 

LOW COOLANT LEVEL.

STOPPING DUE TO 

LACK OF BATTERY

CHARGING (BELT BRE

-

AKAGE).

STOPPING DUE TO 

HIGH ENGINE 

TEMPERATURE.

PRESS IF YOU WANT

TO SET WORKING 

TIME                   

 (UP TO 96 HOURS).      

After starting, the motor pump protects itself automatically.

PRESS TO SELECT 

    THE FUNCTION:

 

  

 AUTOMATIC

 

 

 

         

OFF/RESET 

 

 

         MANUAL

 

  

CUMULATIVE ALARM

 

WITHOUT

STOP

WITH

STOP

BRIEF INSTRUCTIONS

CLOCK

Содержание 00211143

Страница 1: ...pressure of the system constant accelerator with 2 wires connected to the control unit Controls the flow of water in the pipe Electronic pressure switch to control the pump water pressure Digital pum...

Страница 2: ...SPLAY CHANGES HOLD DOWN TO SI LENCE THE GENERAL ALARM BUZZER PRESS UNTIL THE 2 SIGNS START FLASHING TO EXCLUDE PUMP PROTECTION TO RE ACTIVATE PROTECTION PRESS AGAIN UNTIL THEY SWITCH OFF PRESSTOSTART...

Страница 3: ...iming Pump priming failure 5 Operation Clutch Engine warming Engine cooling Stop Emergency stop Stop with the Stop and Off Reset buttons Stopping failure Buzzer 6 Operation Timer Resetting of the set...

Страница 4: ...SSURE SWITCH Press to select the pump water pressure gauge FAILURE TO FILL PIPES FAULT The acceleration starts with the engine running with pump primed The motor pump reaches the redefined WORKING PRE...

Страница 5: ...if the pump has not started up after the fourth pulse It is obtained with measurement of the voltage and frequency of the battery charging alternator Disables the starter motor The priming pump start...

Страница 6: ...ng buttons the engine stops after slow deceleration Stopping can be obtained in two ways With electromagnet de energized with engine running and energized with it stopped remaining in this condition f...

Страница 7: ...display the end of work time indicator comes on The work time is set by pressing the push button lights up until the desired value appears on the DISPLAY On releasing the push button the timer automat...

Страница 8: ...th running engine 2 YES SLOW YES WITH STOP The temperature detected by the transmitter exceeds the set threshold FUEL RESERVE FUEL RESERVE Flashing FUEL FLOAT TERMINAL T Always active 5 10 NOT NOT DOE...

Страница 9: ...of the intervention delay INSUFFICIENT PUMP WATER PRESSURE INSUFFICIENT WATER PRES SURE ELECTRONIC PRESSURE SWITCH After detection of working pressure and in any case 600 after the pump started 5 YES...

Страница 10: ...OWN only for permanent magnet WHITE YELLOW ORANGE BLACK BATTERY STOP SYSTEMS SEE PAGE 11 ORANGE BLUE INDICA TOR W RESERVE ACCELERATOR YELLOW GREEN BLACK BLUE ORANGE BROWN WHITE VIOLET CABLE 1 5m BLACK...

Страница 11: ...ER and the oil PRESSURE GAUGE connect the transmitters to the respective wires of the unit then CUT and isolate the BLACK VIOLET wire WARNING IT IS NOT POSSIBLE TO MOUNT THE EMERGENCY STOP BUTTON ON A...

Страница 12: ...g pump P2 starts when the water reaches the priming probe lthe pump stops PRIMING FAILURE The pump is stopped if the priming probe does not sense the presence of water within 240 sec To connect PUMP P...

Страница 13: ...hased from a telephone provider on any contract the PIN needs to be disabled To do this it is necessary to insert the SIM in a normal private use cell phone then enter the PIN supplied by the provider...

Страница 14: ...ght left Push to view the first second or third subscriber Press and wait for OK to be written MOB 1 MOB 1 123456789 333456789 NOTIFIED MOB 1 333 Notifies via SMS message when the motor pump is in ala...

Страница 15: ...ion exclusion After the switch off command the following is displayed After the command to delete switching off the following is displayed After the command the following is displayed After the comman...

Страница 16: ...stopped STOP MOTOR PUMP START WATER PRESSURE HOURS OF OPERATION FUEL FAULT The fuel fault depends on any change in the fuel level in the motor pump tank when the engine is stopped The check up is ena...

Страница 17: ...CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS Where the environmental temperature is outside the limits indicated in the Technical Data Where the air pressure and temperature...

Страница 18: ...tes Decreases Increases Decreases Increases Set the engine revolutions read on the portable tachometer Press and wait for OK to be written Press and wait for OK to be written Press and wait for OK to...

Страница 19: ...ming pump yellow blue pump clutch white yellow 3A 40A 3A 3A 3A 3A Temperature range 10 60 C MODEM B1 B3 B5 B7 B8 B20 FDD LTE B1 B5 B8 WCDMA B3 B8 GSM Hour meter 4 digits Engine oil pressure gauge 0 9...

Страница 20: ...Flow switch FAP 200 00500312 ORDERING DATA ACCESSORIES SUPPPLIED Type CIM 137 4G CODE 00211143 CIM 137 4GW CODE 00211151 PRE WIRED CONNECTOR CIM 130 1 6 7 CODE 70804397 TRANSMITTER TYPE TPA 200 CODE 7...

Отзывы: